How To Choose The Right Emergency Lighting For Your Building

Choosing the right emergency lighting sounds like a one-afternoon job. It rarely is. There are decisions about system type, operating mode, siting, battery duration and an ongoing testing regime to keep on top of, and the consequences of choosing wrongly go well beyond a failed inspection.

If you manage a commercial premises, rent out property or hold legal responsibility for a building’s fire safety, this guide is for you. It works through every decision you need to make, in the order you need to make it. It links directly to our emergency lighting products so you can act on what you learn.

What Is Emergency Lighting? Definition, Purpose and Legal Duty

Emergency lighting is installed to illuminate escape routes and key safety points automatically whenever the mains supply fails. The moment normal lighting cuts out, an emergency lighting system kicks in from its own battery power, giving occupants enough light to find an exit and get out safely. Without it, a power failure caused by a fire cutting through a cable, an electrical fault or a grid outage could leave people in complete darkness.

It is worth being clear on one distinction. Emergency lighting covers escape route provision and safety during evacuation. Standby lighting, which keeps normal activities running during a power outage, is a separate category entirely. This guide focuses on emergency escape lighting, because that is what the law requires.

The Legal Framework: RRFSO 2005, BS 5266 and Building Regulations

Under the Regulatory Reform (Fire Safety) Order 2005 (which applies in England and Wales), the responsible person for any non-domestic premises has a legal duty to provide and maintain adequate emergency escape lighting. Equivalent duties apply under the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 in Scotland, and under the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 in Northern Ireland.

Building Regulations 2010, Approved Document B, also requires emergency lighting in new builds and major renovations. The standard that tells you how to meet these legal duties is BS 5266-1:2025, the current code of practice for emergency lighting of premises (the 2025 edition came into effect on 31 October 2025, replacing the previous 2016 edition). It is not legislation itself, but it is the standard against which compliance is assessed by fire inspectors and insurers alike.

Do You Actually Need Emergency Lighting in Your Building?

Most non-domestic buildings require emergency lighting. But the specific requirement depends on the building, its occupancy type and what your fire risk assessment identifies. So before anything else, ask yourself: would a loss of mains lighting put the people in my building at risk?

If the answer is yes in any part of the building, emergency lighting is needed there. That typically covers escape routes, stairways, corridor junctions, changes in floor level, toilet facilities over 8m², plant and control rooms, and anywhere fire-fighting equipment or alarm call points are located.

There are narrow exceptions. BS 5266-1 notes that a room of no more than 12m² with no specific risks identified does not require emergency lighting, provided it is not itself an escape route from another room. A single-occupancy toilet for an able-bodied person is also exempt. But these are edge cases. When in doubt, a fire risk assessment will give you a clear, premises-specific answer.

Emergency Lighting for an HMO: What Landlords Need to Know

For landlords managing houses in multiple occupation, emergency lighting for an HMO is often a condition of your licence, not just a recommendation. Local authorities frequently require it in communal areas: entrance halls, stairwells and shared corridors. Individual rooms are generally treated as domestic spaces, but communal areas are not. Check your local authority’s HMO licensing conditions alongside your fire risk assessment to confirm exactly what applies to your property.

Emergency Lighting Types: Escape Routes, Open Areas and High-Risk Zones

Understanding the different emergency lighting types is the foundation of any compliant installation. The distinctions are not just technical. They affect which products you buy, where you put them and what illumination levels you need to achieve.

1

Escape route lighting is the most common type you will encounter. It illuminates the designated escape routes through a building so people can move safely toward exits. Under BS 5266-1:2025, the minimum horizontal illuminance on the floor of the whole escape route is 1 lux, excluding a border zone at each side.

2

Open area lighting (sometimes called anti-panic lighting) serves larger, open spaces: atria, open-plan floors, assembly halls. In these spaces, the risk is that people cannot identify which direction leads to an escape route, rather than not being able to see the route itself. The minimum requirement is 0.5 lux across the core floor area, excluding a 0.5m border around the perimeter.

3

High risk task area lighting applies wherever people are carrying out dangerous activities: operating machinery, managing a production line, running a control room process. A sudden loss of light in these areas creates an immediate physical hazard, so illuminance must be at least 10% of the normal maintained lighting level for that task, and never less than 15 lux.

All three are forms of emergency escape lighting and are subject to the legal requirements under the Regulatory Reform (Fire Safety) Order 2005. With the types understood, the next question is how your chosen luminaires should behave during normal use.

Maintained vs Non-Maintained Emergency Lights: Which Mode Does Your Building Need?

This is one of the most consequential decisions in the whole process, and it comes down to how your building is used.

1

Non-Maintained Emergency Lighting

Non-maintained emergency lighting is off during normal building operation. It detects the loss of mains power and switches on automatically from its battery. It is the standard choice for workplaces where artificial lighting is in use whenever the building is occupied: offices, warehouses, schools, care homes, retail premises. Cost-effective, straightforward to install and widely used across the UK.

2

Maintained Emergency Lights: When You Need Them

Maintained emergency lights are on continuously. They run from the mains during normal use and switch to battery power when the mains fails. They are required in places of public assembly where dimmed or low lighting is in use: cinemas, theatres, nightclubs and entertainment venues. They are also the standard choice for illuminated exit signs in public spaces, even in well-lit areas, because they provide clear route guidance during any evacuation regardless of whether the power has failed.

3

Combined Emergency Lighting

Combined emergency lighting contains two or more lamps, with at least one on the emergency supply and the others on mains. These are also called switchable emergency lights. A combined emergency luminaire can operate in either maintained or non-maintained mode, which makes them a flexible choice in buildings where different areas have different requirements.

Not sure which mode your premises needs? BS 5266-1 contains a detailed list of premises types and the recommended mode for each.

Self-Contained vs Central Battery Emergency Lighting Systems

Once you know your operating mode, you need to decide how your system is powered. There are two fundamentally different approaches, and the right one depends on the size and complexity of your building.

Self-Contained Emergency Lighting: The Most Common Choice

Self-contained emergency lighting is the most widely installed solution for smaller and medium-sized premises across the UK. Each luminaire has its own built-in battery. When mains power fails, the battery in that individual unit activates the emergency lamp. If one fitting fails, the rest of the system carries on. No dedicated battery room is needed, installation uses standard wiring and the system is straightforward to extend.

The trade-off is that batteries in individual units are exposed to varying temperatures, which can affect their service life. Battery replacement cycles are typically every three to four years, depending on battery chemistry and the manufacturer’s specification.

Central Battery Emergency Lighting Systems

Central battery systems power slave luminaires throughout the building from a single battery source. Maintenance is managed from one location, battery life is significantly longer for large battery banks and the slave luminaires themselves tend to be less expensive. The upfront investment is higher, fire-resistant cable is required between the central battery and every slave luminaire, and a fault in the central unit can affect a large section of the system at once.

For most offices, schools, care homes and retail premises, self-contained fittings are the practical choice. Central battery systems tend to be specified for large, complex buildings: hospitals, multi-storey commercial developments and venues with specific resilience requirements.

Battery Emergency Lighting and LED Emergency Lights: Why LED Is Now the Default

The vast majority of new emergency lighting installations in the UK now use battery emergency lighting with LED light sources. Emergency LED lighting has largely replaced fluorescent and incandescent technologies, and for good reason.

LED emergency lights consume far less power. That means a smaller battery can deliver the same duration of illumination. LED lamps also last longer and tolerate frequent switching better than older technologies, which matters in maintained fittings and during regular test cycles. Because LED emergency lighting draws less current from the battery, it tends to maintain consistent output across the full emergency duration rather than dimming as the battery discharges.

If you are replacing older fittings, upgrading to LED emergency lights makes sense on every measure: running costs, replacement frequency and performance. Modern LED emergency fittings are available across every form factor: bulkheads, downlights, battens and exit signs.

Plug In Emergency Lighting: What It Can and Cannot Do

Plug in emergency lighting refers to portable, socket-fed units that require no hardwired installation. They have genuine uses, but it is important to understand their limits before buying.

For commercial premises subject to the Regulatory Reform (Fire Safety) Order 2005, plug in units are not a substitute for a fixed, commissioned and certified installation. A fire inspector will expect to see hardwired fittings with a proper commissioning certificate and test records.

That said, plug in emergency lighting does have a place. It can provide temporary cover during building works or fit-outs. It can supplement fixed lighting in specific locations where a permanent installation is being planned.

Emergency Lighting for the Home

There is currently no legal requirement for emergency lighting in private dwellings. Homeowners asking about emergency lighting for the home are not dealing with the same compliance landscape as commercial premises. Even so, rechargeable socket-mounted emergency lights or portable emergency torches are a practical precaution, particularly in larger properties or homes where occupants have mobility considerations.

Where Emergency Lighting Is Installed: Siting Luminaires Correctly

Knowing where to put your luminaires is as important as choosing the right ones. BS 5266-1 and BS EN 1838 both set out clear requirements on positioning, and the principle is consistent: people must always be able to see where the exit is and locate any safety equipment, regardless of how far they can see across the building.

The standard identifies key points of emphasis where a luminaire must be positioned. These are:

  • Each exit and final exit door
  • Every change of direction along an escape route
  • Each stairway, so that every step receives direct light
  • Each intersection of corridors
  • Near each fire alarm call point
  • Near each piece of fire-fighting equipment
  • Outside each final exit, to illuminate the area immediately beyond
  • In lift interiors, where lifts form part of the evacuation plan identified in the risk assessment
  • Toilet areas over 8m² (and all toilets accessible to disabled people)

That list is a starting point, not an endpoint. Once all points of emphasis are covered, designers must also check whether additional luminaires are needed to achieve the minimum illuminance levels along the full length of escape routes. Every escape route compartment must have at least two luminaires, so that if one fails, the route remains lit.

Exit signs should use the pictogram format specified in BS EN ISO 7010 and be illuminated wherever the route to a final exit is not immediately visible.

How Long Must Emergency Lighting Last? Duration Requirements Explained

Duration is more misunderstood than almost any other aspect of emergency lighting, so it is worth being precise.

The minimum duration for emergency escape lighting is one hour. But a one-hour duration is only acceptable if the building will be completely evacuated immediately on mains failure and not reoccupied until the batteries have fully recharged. That is a narrow set of circumstances.

For most premises, including any building with sleeping accommodation and any building that might be reoccupied soon after a power failure, the required minimum duration is three hours. Hotels, care homes, student accommodation, residential blocks and HMOs all fall into this category. Three hours is also the standard for the annual full duration test.

When you are specifying or purchasing fittings, always check the duration rating on the product. A unit rated for one hour is not appropriate for sleeping accommodation or premises that may be reoccupied quickly after a power failure.

Self-Test Emergency Lighting: Reducing Your Compliance Burden

Self-test emergency lighting is one of the most practical developments the industry has produced in recent years. These are luminaires with a built-in test module that runs automatic functional tests and logs the results, with no manual intervention required from you or your team.

Think about what manual testing involves on a large site. Someone flicks a switch or isolates a circuit, then walks the entire building checking every luminaire is working. They restore the supply, then walk the building again to confirm every unit is recharging. Then they record it all. In a building with dozens or hundreds of fittings, that process takes hours and causes real disruption to occupants.

Emergency lighting is not normally linked to the fire alarm system. It is usually triggered by a failure of the normal electrical supply, although some buildings may have additional links or integrations between the two systems.

To ensure these units are ready when needed, self-testing emergency lighting handles the required monthly flick test automatically. The unit runs a short simulated mains failure at a preset time, checks that the emergency lamp activates, confirms the battery is holding charge, and flags any faults via an indicator light. In more sophisticated systems, a remote monitoring panel or addressable test system collects results from all fittings in one place. You still need to review the results and address any failures, but the testing itself happens without you.

For responsible persons managing multiple buildings or busy commercial premises, self-test emergency lighting is worth the additional upfront cost. It reduces the risk of tests being missed, and a missed test is a compliance gap.

Emergency Lighting Testing: The Flick Test, Full Duration Test and Record-Keeping

Emergency lighting systems are only useful if they work when called upon. Testing is a legal obligation, set out in BS EN 50172:2024 and BS 5266-1:2025. Here is what the standards require.

1

Monthly Testing: The Flick Test

The flick test must be carried out every month. It is a short functional test that simulates a mains failure long enough to confirm the luminaire activates and the battery is holding charge, but short enough to avoid unnecessarily depleting it. Every luminaire and exit sign must be checked to confirm it is present, clean and operating correctly. The results must be recorded in the emergency lighting section of your fire safety log book.

2

Annual Testing: The Full Duration Test

The full duration test must be carried out once a year. The primary lighting circuit is switched off and the emergency lighting system must run for its full rated duration (typically three hours), remaining fully operational and maintaining adequate lux levels throughout. All luminaires and signs are checked at the start, during and at the end of the test. Any failures must be recorded and remedied promptly.

Full duration tests should be timed to minimise disruption and allow batteries to recharge fully before the building returns to normal occupation. Many organisations schedule the annual test alongside fire alarm maintenance, because the waiting time during the drain test can be used productively.

3

Five-Year Photometric Verification

BS 5266-1:2025 introduced a further requirement that was not present in earlier editions: photometric verification every five years. This goes beyond switching fittings on to check they activate. It involves measuring actual illuminance levels across the building to confirm the system still delivers the light output the original design specified. Ageing lamps, layout changes and obstructions can all reduce performance over time, and the five-year check is the formal mechanism for catching that drift before it becomes a compliance failure.

4

Central Battery Systems: Daily Inspection

For central battery systems only, a daily visual inspection of the central power supply indicators is also required. This confirms the system is operational. It does not involve testing the luminaires themselves.

The results of all tests, including failures and the remedial action taken, must be logged in an emergency lighting log book. We offer a free digital fire safety log book with dedicated sections for emergency lighting test records. An emergency lighting test sheet kept up to date is not just good practice. It is required under BS 5266-1 and may be requested during a fire safety inspection.

Emergency Lighting Certificates: What You Need and When

When a new emergency lighting system is installed, the installer provides a commissioning certificate confirming the system meets the relevant standards at the point of installation. This is your emergency lighting certificate for the initial installation.

Beyond commissioning, the annual full duration test should be documented with an emergency lighting periodic inspection and testing certificate. This records who carried out the test, when, and what the results were. Together, the commissioning certificate and the annual testing certificate form the core of your compliance documentation.

Keep them on site, available for inspection alongside the emergency lighting section in your fire safety log book, and test sheet records. If you manage multiple sites, a consistent approach to record-keeping across all buildings makes audits significantly more straightforward.

How To Meet Regulations for Emergency Lighting: A Practical Summary

Emergency lighting regulations can feel like a tangle of overlapping documents. Standard regulations for emergency lighting draw on legislation, British Standards and European harmonised standards all at once, so this section is a guide to emergency lighting compliance in plain terms: what the documents are, what they require and how they fit together.

Emergency lighting systems are central to building safety for any business, school, care home or rented property. They are not optional, and they are not a box-ticking exercise. Here is how the framework works in practice.

The Regulatory Reform (Fire Safety) Order 2005 is the legal requirement for England and Wales. It requires the responsible person to provide and maintain adequate emergency escape lighting. In Scotland, equivalent duties arise under the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006. In Northern Ireland, they arise under the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010.

BS 5266-1 is the code of practice that shows you how to meet those legal duties. BS EN 50172:2024 sets out minimum testing requirements. BS EN 1838:2024 specifies the illuminance levels required. They work as a hierarchy: legislation sets the obligation, standards define how to fulfil it and product standards govern the equipment itself.

In practice, meeting those regulations means:

  • Having a fire risk assessment that identifies where emergency lighting is needed
  • Installing a system designed and certified by a competent person
  • Carrying out monthly flick tests and annual full duration tests
  • Recording all test results and any remedial action in the emergency lighting section of a fire safety log book
  • Keeping commissioning and periodic inspection certificates on site

There is no threshold below which a non-domestic premises is exempt from these obligations. Small offices, care homes and warehouses all carry the same duty.

Emergency Lighting for Different Building Types

Different buildings have different requirements, and it is worth knowing what applies to your situation before you start specifying products.

Offices

Most offices require non-maintained emergency lighting on all escape routes. Rooms of no more than 60m² that are not themselves part of an escape route from the wider building may not require it, but any corridor, stairway or main exit route must be covered.

HMOs and Rented Properties

Emergency lighting for an HMO is commonly required in all communal areas: entrance halls, stairways and shared corridors. Individual rooms are treated as domestic spaces, but the communal parts of the building are not. Always check your HMO licence conditions.

Care Homes and Sleeping Accommodation

Three-hour battery duration is required across the board. Maintained exit signs are standard in sleeping areas. The fire risk assessment will specify siting in detail.

Industrial and Warehouse Premises

High risk task area lighting requirements may apply in addition to escape route lighting wherever dangerous processes or machinery are present. The fire risk assessment identifies these areas.

Schools and Educational Buildings

Emergency lighting is required on all escape routes, stairways and assembly areas. Self-test fittings are a popular choice for site managers, because they reduce the administration burden significantly.

Choosing Emergency Lighting Products: Where to Start

With all of the above in mind, what emergency lighting products do you actually need?

Start with your fire risk assessment. A fire risk assessment carried out by a competent person will tell you where emergency lighting is required and often indicate the type and mode appropriate for each area of the building.

For most standard commercial premises, self-contained non-maintained LED bulkheads or battens are the practical starting point: reliable, cost-effective and straightforward to maintain. Exit signs should be illuminated, in the correct pictogram format, positioned wherever the route to a final exit is not immediately obvious.

If your premises is a place of public assembly, or if the fire risk assessment identifies areas of higher risk, discuss maintained or combined fittings with a qualified installer. And if you want to reduce your ongoing testing workload, self-test emergency lighting is worth considering. The time saved across monthly flick tests in a building with many fittings adds up quickly, and automatic logging reduces the risk of compliance gaps.

Browse our full range, including emergency LED lighting, self-test units, plug in emergency lighting, exit signs and a fire log book with an emergency lighting section, at our emergency lighting category page. If you need help working out exactly what your building requires, our team is ready to help.

Mel Saunders

Head of Marketing

With over 20 years of experience in content writing, design and marketing, Mel now heads up the Content & Marketing Team at Safelincs. Having been in the fire safety industry for over 5 years, Mel has now developed a deep understanding of some of the critical issues facing the industry. Alongside her team, she aims to support the public with resources and information to help them improve fire safety at home, in the workplace or in 3rd sector organisations.

Fire Evacuation Equipment Explained: What Every Business Needs

When fire strikes, the route to safety has to work for everyone in the building. Not just those who can run. That’s a challenge many businesses haven’t fully thought through until the moment they need to. This guide covers the full range of fire evacuation equipment available, explains who needs what and why, and helps you work out what’s right for your premises. Whether you manage a single office or a portfolio of sites, you’ll find everything here to make confident, compliant decisions.

What Is Emergency Evacuation Equipment?

Emergency evacuation equipment is any device or kit designed to help people escape safely when fire makes normal exit routes unusable. It’s the category that takes over once your alarm has done its job and everyone needs to get out.

The primary purpose of fire evacuation equipment is straightforward: ensure no one is left behind. Lifts can’t be used during a fire. Stairwells may fill with smoke. And not everyone can walk down four flights of stairs unaided. Emergency evacuation and rescue equipment bridges the gap between a functioning alarm and a safe, complete exit.

The category covers a wide range of products, each suited to different building types, occupant needs and risk profiles. Here’s what falls under the umbrella.

1

Evacuation Chairs and Evac Chairs

The most widely used solution for multi-storey commercial and public buildings. They let a trained operator move a person with limited mobility safely down a staircase when lifts are out of the question. We’ll cover these in detail below.

2

Fire Evacuation Slide Sheets

Thin, tough sheets stored under a patient’s mattress. In settings such as hospitals and care homes, a slide sheet means staff can move a bedbound person quickly to safety without needing to transfer them first. They’re compact enough for narrow staircases and tight corridors, which makes them a practical choice where space is genuinely at a premium.

3

Evacuation Sledges

An evacuation sledge sits somewhere between a slide sheet and a stretcher. It offers more padding and support, with safety straps to hold the person securely during movement. Ideal for wheelchair users and those who need greater comfort during an emergency move. Stored in a wall-mounted bag for rapid deployment, a sledge like the Thorpe Mill model is built to travel over concrete, corridors and stairs with a two-person operation.

4

Fire Escape Ladders

A secondary escape route from upper-floor windows when stairwells are blocked. Portable options hook over a window sill and deploy in seconds. Fixed options, such as the Saffold fold-out ladder, bolt to the outside wall and fold flat when not in use. Suitable for homes, HMOs and commercial premises. Fire escape ladders are classified as a secondary means of escape, not a replacement for primary fire exit routes.

5

Fire Evacuation Masks

Also called escape hoods, fire evacuation masks give the wearer up to 15 minutes of filtered, breathable air in a smoke-filled building. Lightweight and portable, one can sit in a desk drawer or hotel bedside cabinet. They’re particularly valuable in high-rise buildings and long escape corridors, where smoke inhalation is a real risk before anyone reaches a final exit.

6

Fire Warden and Evacuation Accessories

The people coordinating an evacuation need to be seen and heard. High-visibility clothing, torches, air horns and megaphones all help fire wardens cut through the noise and confusion of a live evacuation. We stock fire warden kits in basic and premium configurations, both supplied in a carry bag ready to grab at a moment’s notice.

7

Specialist Emergency Evacuation Equipment

Some situations call for equipment beyond the standard range. Bariatric evacuation equipment supports the safe movement of larger individuals. Evacuation chutes offer controlled descent from height for high-rise buildings and tower blocks. And for the smallest building occupants, specialist products such as infant evacuation cots and evacuation aprons ensure even babies can be moved to safety.

Knowing which type of equipment your building needs isn’t always obvious. That’s exactly why a fire risk assessment matters so much, and it’s something we’ll return to throughout this guide.

What Is an Evac Chair?

How Evac Chairs Work

An evac chair is a specialist chair designed to carry a person who can’t manage stairs unaided safely down a flight during an emergency. It’s the standard solution for evacuating people with mobility impairments from multi-storey buildings when lifts are out of use.

Most evacuation chairs for stairs use a friction belt system. The belts make contact with each step as the chair descends, controlling the speed so the chair doesn’t slip or accelerate. The passenger sits in a sling-style seat, secured with a safety belt and often a forehead restraint. The operator guides from behind. On many models, including the popular Evac+Chair 300H MK5, a single person can manage the entire descent.

Evac chairs are classified as Class I Medical Devices. That matters for maintenance and training obligations, both of which carry legal weight.

Which Evac Chair Do You Need?

The Evac+Chair range has been the industry standard since 1982, and covers a variety of situations.

Model Best For Key Feature
300H MK5 Most standard staircases Single-operator descent
500H MK5 Bariatric users (up to 227kg) Suits standard and steep 45° stairs
600H MK5 Difficult access locations Up to four operators
IBEX TranSeat 700H Buildings where reaching ground level requires going up Ascends and descends stairs
Model
300H MK5
Best For
Most standard staircases
Key Feature
Single-operator descent
Model
500H MK5
Best For
Bariatric users (up to 227kg)
Key Feature
Suits standard and steep 45° stairs
Model
600H MK5
Best For
Difficult access locations
Key Feature
Up to four operators
Model
IBEX TranSeat 700H
Best For
Buildings where reaching ground level requires going up
Key Feature
Ascends and descends stairs

The right choice depends on your staircase, the needs of the people you’re planning for and how many trained staff you’ll have available. A general rule often cited is ‘one chair, one floor, one person.’ Your fire risk assessment will determine the specifics.

Evac Chairs vs Other Evacuation Devices

Fire evacuation equipment for disabled people and those with limited mobility isn’t limited to chairs. For people who can’t transfer into a chair at all (common in hospitals, nursing homes and care homes), evacuation sheets and sledges are the appropriate solution. The right choice depends on the building layout, the individual’s needs and the number of trained staff on hand. In many care settings, you’ll need a combination of equipment rather than a single solution.

Why You Need an Evac Chair on Your Premises

Put simply: if your building has stairs and anyone in it relies on a lift to move between floors, you need a plan for what happens when that lift can’t be used. An evac chair is, for most multi-storey commercial buildings, the most practical answer to that question. And the law reflects it.

It’s also worth considering how broadly ‘mobility impairment’ applies in practice. Not all disabilities are visible. Someone with MS, Parkinson’s or COPD may not always need support, but could during a flare-up. A colleague recovering from surgery or a temporary fracture may need assistance for a matter of weeks. A heavily pregnant visitor may need help on certain staircases. A PEEP (Personal Emergency Evacuation Plan) should be in place for anyone identified as potentially needing support, and that plan should be reviewed regularly.

Are Evac Chairs a Legal Requirement?

The Short Answer

No single piece of legislation names evacuation chairs by type as a mandatory requirement. The legal picture is more layered than a simple yes or no, though for most multi-storey buildings, providing an evac chair or equivalent is effectively unavoidable.

The Legal Framework

The Regulatory Reform (Fire Safety) Order 2005 (RRFSO 2005), which applies in England and Wales, places a clear duty on the responsible person to provide a safe and effective means of escape for everyone in the building, including those with mobility impairments. Equivalent fire safety legislation applies in Scotland and Northern Ireland. When lifts go out of use during a fire, anyone who relies on a lift to move between floors needs an alternative. Where a risk assessment identifies that someone in the building requires assistance to evacuate, and an evac chair is the appropriate solution, the responsible person is expected to provide one. The RRO 2005 also places a duty on responsible persons to instruct staff in the safe use of any evacuation chair installed on the premises.

The Equality Act 2010 reinforces this. Failing to make adequate provision for the safe evacuation of disabled building users can constitute a failure to make reasonable adjustments.

Evacuation chair HSE regulations also fall under the Provision and Use of Work Equipment Regulations 1998 (PUWER). PUWER requires that work equipment (including evacuation chairs) is safe for use, properly maintained and only operated by trained users. We offer annual service contracts for the Evac+Chair range to help businesses meet this obligation without the hassle of managing it themselves.

What About Care Homes?

Fire evacuation equipment for care homes carries particular legal weight. Residents are often entirely unable to self-evacuate, and a care provider has a legal responsibility to ensure provisions cover those with little or no mobility. That frequently means a combination of chairs, slide sheets and sledges rather than chairs alone. A single evacuation chair won’t cover every scenario in a residential care setting.

Is Specific Training Needed to Operate an Evacuation Chair?

Training Is a Legal Requirement

Yes, specific training is required. Under PUWER, evacuation chairs may only be operated by people who’ve received adequate information, instruction and training. Using an evac chair without proper training creates real risk of injury to the operator and the person being evacuated. No building should have a chair on the wall with no one who knows how to use it.

What Evacuation Chair Training Covers

Our evacuation chair training is delivered on-site by a fully qualified trainer, covering both the theory and the hands-on practice of safe operation. The certified two-hour session covers theoretical and practical evacuation chair usage, including health and safety advice. Training takes place in your own building, using your own chair and stairwell, which means delegates practise in the actual environment they’ll use in an emergency. That familiarity counts for a lot when the alarm is going off and decisions need to be made in seconds.

For organisations that want to build training capacity internally, a Train the Trainer course is available. It’s a cost-effective way to spread the qualification across a larger workforce without bringing in an external trainer every time a new member of staff needs to be brought up to speed.

How Often Does Training Need Refreshing?

Refresher training is required every three years. It’s also needed when a trained operator leaves, changes role or becomes unable to fulfil the function. If a new fire risk assessment identifies a person who needs evacuation support and a new chair is installed, additional training is required to cover it.

Evacuation equipment and training aren’t two separate boxes to tick. They’re the same obligation. Installing a chair without training staff to use it leaves a gap that a fire risk assessment (and, in the worst case, an incident investigation) will expose.

Can Evacuation Chairs Be Used by Anyone?

Only trained operators should use an evac chair. The friction belt system and the posture required to guide a chair safely down stairs take practice. Getting it wrong puts both the operator and the passenger at serious risk.

That said, evac chairs are designed to be operable without exceptional physical strength. Many models can be managed by a single operator. What matters isn’t strength, it’s training. Anyone who might be called upon to operate a chair in an emergency should have completed the appropriate course and had hands-on practice beforehand.

What Items Are Included in an Emergency Evacuation Kit Bag?

Fire Warden Kit Contents

A fire warden kit bag is the practical, grab-and-go solution for whoever is responsible for coordinating an evacuation. It brings together the tools a fire warden needs to do their job, stored in a single bag they can reach for immediately.

We supply fire warden kits in two configurations.

The Basic kit contains a fire warden hi-vis waistcoat (conforming to EN ISO 20471), a torch, a gas horn, two emergency lightsticks and a drawstring bag.

The Premium kit builds on this considerably: a fire warden cap, a telescopic sign, a 10W megaphone, a torch, a gas horn, a photoluminescent armband, ten emergency lightsticks, ten emergency whistles and a red carry bag.

Why the Kit Contents Matter

The logic behind these kits is practical. When a fire alarm sounds and people are moving quickly through a building, a fire warden needs to be instantly identifiable (to staff, visitors and anyone else on site who may not know who to follow). A hi-vis waistcoat with the warden’s role clearly marked takes care of that immediately.

The audible tools (the horn, megaphone and whistles) mean the warden can be heard as well as seen, even in noisy or smoke-affected conditions. In a busy building with multiple floors, that communication capability can make the difference between an orderly evacuation and a chaotic one.

Under the RRO 2005, all businesses in England and Wales are required to have at least one fire warden and to carry out regular fire drills. A fire warden kit is one of the simplest ways to make sure the person taking on that role has what they need to do it properly. It’s also one of the easiest things to overlook until it’s too late.

So, whether you’re buying your first evac chair, reviewing the fire evacuation equipment for disabled people you have in place, or putting together a kit for your fire warden, the starting point is always the same: a current, thorough fire risk assessment. That’s what tells you what you need, where it should go and who should be trained to use it. If you’d like help working out what’s right for your premises, our team is available by phone or live chat.

Mel Saunders

Head of Marketing

With over 20 years of experience in content writing, design and marketing, Mel now heads up the Content & Marketing Team at Safelincs. Having been in the fire safety industry for over 5 years, Mel has now developed a deep understanding of some of the critical issues facing the industry. Alongside her team, she aims to support the public with resources and information to help them improve fire safety at home, in the workplace or in 3rd sector organisations.