Fire Door Safety Week: Have You Checked Your Fire Doors Recently?

freedor-on-firedoorFire doors are absolutely crucial when it comes to delaying the spread of fire throughout a building. Effective compartmentalisation can be the difference between losing a single room, and losing an entire property to fire.
Fire Door Safety Week 2015 runs from the 14th until the 20th of September and is intended to help raise awareness of the importance of fire doors whilst encouraging building owners to check the condition of any fire doors they have installed.

Well maintained fire doors provide usually a minimum 30 minute barrier to prevent fire passing through, but to do so, the door must be closed. It is illegal to wedge open fire doors or hold them open with, for example, a fire extinguisher, and business owners leave themselves open to hefty fines and even jail sentences if they fail to prevent this from happening.

A simple way of addressing this problem is the Dorgard Fire Door Retainer and the Freedor Wireless Free Swing Door Closer, which  are legal ways of holding fire doors open. These devices allow doors to be retained in an open position, but automatically release the door in the event of a fire alarm, meaning the fire barrier is re-instated when a fire is detected. Commonly found in public buildings or commercial premises, they offer the perfect solution to a common problem.

Of course, making sure that fire doors are closed when needed means nothing unless the fire door creates a good seal. If you can see daylight at any point around the perimeter of your fire doors, then something is certainly wrong. Fire doors or their frames should feature an intumescent seal to prevent flames or smoke from passing through any small gaps. These fire door seals often feature a brush-like element which is intended to prevent smoke from getting past. This seal should snugly fill the small gap between door and frame.

A simple way to test the performance of the brush element of your fire door seals is to insert a postcard (or something similar) into the gap around the door. If the seal is in good condition, this should be held in place. If the seal does not grip the card then it may warrant replacement as the brush has likely worn over time. The condition of your fire door seals must be checked periodically. If they are found to be worn or missing, it is advisable to replace them immediately.

Fire door seals come in two main types: self-adhesive surface mounted seals, or rebated seals which are sunk into the door or frame. Once again, it is a legal responsibility to ensure your fire doors and their seals are in good condition. If it were found that the maintenance of the fire doors had been neglected, then the responsible person  could be prosecuted.

We hope this article encourages you to ensure your fire doors and seals are in good condition. Making sure your fire doors are in good order, and preventing them from being wedged open is a simple task that can make a world of difference in the event of a fire. Spend just a few minutes today to ensure your fire doors are protecting your property as well as they can.

For further information about fire doors and related products, visit our fire door help & information page, or contact us on 0800 612 6537.

Please also reference our fire safety forum section

Fire Door Safety Week – 16 -21 September

Fire doors save lives and property. Fire Door Safety Week is all about raising awareness of this critical element of fire safety in every commercial, public and multiple occupancy building. The British Woodworking Federation, with a number of industry partners has created Fire Door Safety Week to:

raise awareness of the critical role of fire doors, drawing attention to specific issues such as poor installation and maintenance.

  • encourage building owners and users to check the operation and condition of their fire doors and to report those that aren’t satisfactory.
  • engage and educate people, helping with the whole building industry and every property owner to understand the correct specification, supply, installation, operation, inspection and maintenance of fire doors.

Safelincs supports this campaign and offers information about fire doors. Safelincs also offers a range of standard (FD30 – 30 minute) fire doors which are available in the most common sizes, styles and colours including 4 panel, 6 panel and glazed with a variety of shapes of pane.

In addition we can supply custom built fire doors to your particular specification. Our simple online system allows you to easily configure and order a custom FD30 fire door within minutes. You can choose it with or without frame with your specified features including veneer, design and glazing options.

All standard fire doors have a delivery lead time of 7-10 working days from the date of order. Customised made-to measure doors have a delivery lead time of 1-3 weeks.

Safelincs also provide a range of associated products including fire door closers, fire door seals and hinges.

It is illegal to wedge open fire doors but with Dorgard it is possible to hold fire doors open legally to make access to rooms easier. These fire door retainers will hold a door open but immediately a smoke alarm sounds the sonic waves trigger the release mechanism allowing the door to close.