The Ei164eRF mains powered heat alarm with self-charging lifetime back-up battery is supplied with a RadioLINK module to enable wireless interlinking with multiple alarms via radio-frequency. Up to 12 smoke and heat alarms from the Ei160e series can be interlinked without the need for cables between each unit. Specifically designed for use in kitchens and garages, the heat alarm activates when there is an increase in temperature, therefore avoiding false alarms from cooking fumes.
- Power: 230V mains powered with back-up battery
- Backup Battery: Self-charging battery
- Warranty: 5 year warranty
- CE marked and Kitemarked to BS 5446-2: 2003
- Suitable for installations complying to Grade D1
- Consists of a RadioLINK module and an Ei164e heat alarm
- Heat sensor - activates at 58 °C to avoid false alarms from cooking fumes
- Up to 12 smoke and heat alarms can be interlinked within the same system
- Requires no cables between each unit - wireless interlinking
- Radio-frequency range: 100m in free space, up to 30m in buildings
- Sealed back-up battery designed to last the life of the alarm (10 years)
- Ideal where annual battery replacement would be inconvenient
- RadioLINK module simply plugs into the back of the alarm
- Test and hush button facility
- Memory feature - easy to identify an alarm that has previously activated
- Suitable for kitchens and garages
- Supplied with fixings; 2 x screws and 2 x rawl plugs
- This alarm is also suitable for the updated 2022 Scottish legislation for fire alarms in homes
The table below shows all the units that can interlink with the EI166ERF.
Smoke and Heat Alarms - Radio
Model Number
|
Type of Unit
|
Type of Interlink
|
Ei3014 / Ei3014RF |
Mains Powered Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3016 / Ei3016RF |
Mains Powered Optical Smoke Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3024 / Ei3024RF |
Mains Powered Optical & Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3028 / Ei3028RF |
Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei2110e / Ei2110eRF |
Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei161e / Ei161eRF |
Mains Powered Ionisation Smoke Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei164e / Ei164eRF |
Mains Powered Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei166e / Ei166eRF |
Mains Powered Optical Smoke Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei141 / Ei168RC141RC |
Mains Powered Ionisation Alarm - 9V Alkaline |
Hardwire or Radio Interlink |
Ei144 / Ei168RC144RC |
Mains Powered Heat Alarm - 9V Alkaline |
Hardwire or Radio Interlink |
Ei146 / Ei168RC146RC |
Mains Powered Optical Smoke Alarm - 9V Alkaline |
Hardwire or Radio Interlink |
Ei3100RF |
Battery Powered Ionisation Smoke Alarm - 9V Alkaline |
Radio Interlink |
Ei3103RF |
Battery Powered Heat Alarm - 9V Alkaline |
Radio Interlink |
Ei3105RF |
Battery Powered Optical Smoke Alarm - 9V Alkaline |
Radio Interlink |
Ei603RF |
Battery Powered Heat Alarm - Sealed Lithium |
Radio Interlink |
Ei650RF |
Battery Powered Optical Smoke Alarm - Sealed Lithium |
Radio Interlink |
Carbon Monoxide Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei3018 / Ei3018RF |
Mains Powered Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3028 / Ei3028RF |
Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei262 |
Mains Powered Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei261 |
Mains Powered Carbon Monoxide Alarm - Sealed Lithium |
Hardwire Interlink |
Ei208WRF |
Battery Powered Carbon Monoxide Detector - Sealed Lithium |
Radio Iinterlink |
Ancillary Products
Model Number
|
Type of unit
|
Type of interlink
|
Ei170RF |
Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium |
Radio Interlink |
Ei407 |
Battery Powered Manual Call Point - Sealed Lithium |
Radio Interlink |
MCP401RC |
Mains Powered Manual Call Point |
Hardwire Interlink |
Ei450 |
Battery Powered Fire and CO Alarm Controller - Sealed Lithium |
Radio Interlink |
Ei411H |
Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium |
Radio Interlink |
Ei410TRF |
Battery Powered Test Remote - Sealed Lithium |
Radio Interlink (Ei3100RF Series) |
Ei1529RC |
Mains Powered Locate, Silence & Test Control Switch |
Hardwire Interlink |
Ei159 |
Mains Powered Smoke Alarm Locator Switch |
Hardware Interlink |
Ei428 |
Mains Powered 5A Relay Module |
Radio Interlink |
Ei128R |
Mains Powered 5A Relay Module |
Hardwire Interlink |
Ei128RBU |
Mains Powered 5A Relay Module with Lithium Backup Battery |
Hardwire Interlink |
Y03 |
Mains Powered Multi Frequency Sounder |
Hardwire Interlink (via relay) |
SAB300C |
Mains Powered Flashing Xenon Strobe (Clear) |
Hardwire Interlink (via relay) |
SAB300R |
Mains Powered Flashing Xenon Strobe (Red) |
Hardwire Interlink (via relay) |
Wiring Explained
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-