Suitable for kitchen and garage installations, the Ei3028RF is a mains powered, multi-sensor, heat and carbon monoxide alarm with a built-in, rechargeable lithium back-up battery. Complete with AudioLINK technology, this alarm allows you to extract real time data from the alarm directly to a smart phone. The alarm is fitted with a high performance heat and electrochemical sensor to provide protection from both fire and CO in one alarm. Also supplied with a Ei3000MRF SmartLINK module, which allows for hybrid (wired or wireless) interlinking with up to 12 compatible devices, the alarm features a combined test and silence button to facilitate frequent testing of the alarm and system.
Product Lifespan: 10 years
Power: 230V mains powered with battery backup
Backup Battery: Re-chargeable lithium battery
Warranty: 5 year warranty
Suitable for ceiling installation
Contains both a heat and electrochemical carbon monoxide sensor
Suitable for kitchen and garage installations
Real time data extraction to a smart phone via AudioLINK
85dB warning alarm at 3m
Different alarm sounds based on which sensor has been triggered
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-
Q. Where should I install carbon monoxide detectors?
A.
CO detectors should be installed near boilers and other potential sources of carbon monoxide. Keep a 1 to 3 meter distance to the boiler etc to avoid small start-up CO discharges to cause false alarms.
As you are likely to be most affected by CO in areas of your home that you spend the most time in it is advisable to install detectors in those areas as well, such as the living room and bedrooms.
It is also worth noting that while one detector is better than no detectors at all, larger homes may require several detectors to cover the property fully.
Which areas to avoid?
Do not install CO alarms above or below windows.
Although most kitchens contain fuel burning appliances it is not recommended to install your detector there. Kitchens can be quite steamy while you are cooking and this may affect the sensor in the CO detector. Similarly it is not recommended to install detectors in dusty areas such as workshops or garages.
Q. How do I safely dispose of my old smoke alarms?
A.
Safelincs is signed up to Valpak's WEEE (Waste Electrical and Electronic Equipment) Distributor Take-Back Scheme (Registration ID: 7370). Private households can therefore drop off their electronic and electrical fire safety waste at their municipal recycling centre when they are purchasing new products from us. To find your nearest recycling centre, please visit www.recycle-more.co.uk.
Q. Can the mains powered smoke alarm range be connected to mains power via the lighting circuit?
A.
Yes, hard-wired mains powered alarms can be wired to the unswitched live feed of the nearest frequently used lighting circuit.
Q. How long do the batteries last in smoke alarms?
A.
The 9V alkaline batteries last 12-18 months. Lithium batteries will usually last 5x longer than their alkaline counterparts, achieving around 5 years lifetime. Some lithium cells are also rechargeable, and when used in a mains-powered alarm may last for the entire functional lifespan of the alarm. Newer alarm models may also feature a "sealed" lithium battery. These batteries are specialist components which are designed to not be removed or need replacing by the user, and have been tested by the alarm manufacturer to ensure they last for the lifetime of the alarm.
Please Note: the actual lifetime of your batteries depends on how often the alarms are tested or activated, as sounding the alarm draws more power than when the alarms are "waiting" to detect fire. You should also read your alarm's manual to make sure you only use the recommended types and brands of batteries, as failing to follow these instructions may cause the alarm to malfunction, not alerting you in the event of a fire, and might also invalidate the warranty.
Q. When the test button is pressed on an interlinking smoke alarm will this cause all the other units to go off, too?
A.
Yes, by pressing the test button on one alarm all the units in that family will also be activated. To 'teach' the units which other smoke alarms belong to the same family, the smoke alarms have to be set up together during the installation. This is done by pressing a 'housecoding button' or similar process.