CALL OUR TEAM NOW 0800 612 6537 Lines open today 8am - 6pm

Mains Radio-Interlinked Ionisation Smoke Alarm with Self-Charging Battery - Ei161eRF

Discontinued Product

This product has been discontinued.

alternative product

Mains Radio-Interlinked Optical Smoke Alarm with Back-up - Ei3016RF

  • Power: 230V mains powered with back-up battery
  • Backup Battery: Self-charging battery
    • Warranty: 5 year warranty
    • Supplied with Ei3000MRF SmartLINK module
    • Radio-interlink with up to 12 devices
    • Extract real time data to their smart phone
    • CE and Kitemarked to BS EN 14604: 2005
    • Also suitable for both the Welsh and Scottish 2022 legislation

    £99.79 inc VAT

    £83.16 ex VAT

    View Product
    Product Overview

    Supplied with a RadioLINK module, the Ei161eRF is a mains powered ionisation smoke alarm with sealed self-charging back-up battery and wireless interlink feature. The RadioLINK module allows the Ei161eRF to radio-interlink with up to 12 other smoke and heat alarms within the same system, avoiding the mess, cost and time associated with hard-wire interlinking. The sealed back-up battery is designed to last the 10 year life of the alarm without requiring replacement.

    • Power: 230V mains powered with back-up battery
    • Backup Battery: Self-charging lifetime battery
    • Warranty: 5 year warranty
    • CE marked and Kitemarked to EN 14604: 2005
    • Suitable for installations complying to BS 5839-6: 2019 Grade D1
    • Consists of a RadioLINK module and an Ei161e smoke alarm
    • Ionisation smoke sensor - quick to detect fast flaming fires
    • Up to 12 smoke and heat alarms can be interlinked within the same system
    • Wireless interlink - requires no cables between each unit
    • Radio-frequency range: 100m in free space, up to 30m in buildings
    • Sealed back-up battery designed to last the 10 year lifespan of the alarm
    • Ideal for use where changing batteries would be inconvenient
    • RadioLINK module simply plugs into the back of the alarm
    • Test and hush button facility
    • Memory feature - easy to identify an alarm that has previously activated
    • Suitable for upstairs landing areas
    • Supplied with fixings; 2 x screws and 2 x rawl plugs
    Interlink

    The table below shows all the units that can interlink with the Ei161eRF.

    Smoke and Heat Alarms - Radio

    Model Number
    Type of Unit
    Type of Interlink
    Ei3014 / Ei3014RF Mains Powered Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei3016 / Ei3016RF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei3024 / Ei3024RF Mains Powered Optical & Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei2110e / Ei2110eRF Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei161e / Ei161eRF Mains Powered Ionisation Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei164e / Ei164eRF Mains Powered Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei166e / Ei166eRF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei141 / Ei168RC141RC Mains Powered Ionisation Alarm - 9V Alkaline Hardwire or Radio Interlink
    Ei144 / Ei168RC144RC Mains Powered Heat Alarm - 9V Alkaline Hardwire or Radio Interlink
    Ei146 / Ei168RC146RC Mains Powered Optical Smoke Alarm - 9V Alkaline Hardwire or Radio Interlink
    Ei3100RF Battery Powered Ionisation Smoke Alarm - 9V Alkaline Radio Interlink
    Ei3103RF Battery Powered Heat Alarm - 9V Alkaline Radio Interlink
    Ei3105RF Battery Powered Optical Smoke Alarm - 9V Alkaline Radio Interlink
    Ei603RF Battery Powered Heat Alarm - Sealed Lithium Radio Interlink
    Ei650RF Battery Powered Optical Smoke Alarm - Sealed Lithium Radio Interlink

    Carbon Monoxide Alarms

    Model Number
    Type of unit
    Type of interlink
    Ei3018 / Ei3018RF Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei262 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
    Ei261 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink
    Ei208WRF Battery Powered Carbon Monoxide Detector - Sealed Lithium Radio Iinterlink

    Ancillary Products

    Model Number
    Type of unit
    Type of interlink
    Ei170RF Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium Radio Interlink
    Ei407 Battery Powered Manual Call Point - Sealed Lithium Radio Interlink
    MCP401RC Mains Powered Manual Call Point Hardwire Interlink
    Ei450 Battery Powered Fire and CO Alarm Controller - Sealed Lithium Radio Interlink
    Ei411H Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium Radio Interlink
    Ei410TRF Battery Powered Test Remote - Sealed Lithium Radio Interlink (Ei3100RF Series)
    Ei1529RC Mains Powered Locate, Silence & Test Control Switch Hardwire Interlink
    Ei159 Mains Powered Smoke Alarm Locator Switch Hardware Interlink
    Ei428 Mains Powered 5A Relay Module Radio Interlink
    Ei128R Mains Powered 5A Relay Module Hardwire Interlink
    Ei128RBU Mains Powered 5A Relay Module with Lithium Backup Battery Hardwire Interlink
    Y03 Mains Powered Multi Frequency Sounder Hardwire Interlink (via relay)
    SAB300C Mains Powered Flashing Xenon Strobe (Clear) Hardwire Interlink (via relay)
    SAB300R Mains Powered Flashing Xenon Strobe (Red) Hardwire Interlink (via relay)

    Wiring Explained

    Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.

    To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-

    Wiring Mains Powered Alarms

    Technical Data
    Product Code EI161ERF
    Alternative Product Codes Ei161, Ei161e, Ei161eRF
    Brand EI Electronics
    Back-Up Battery

    Self-charging Lithium Battery

    Dimensions (HxDia)

    54x148mm

    Operating Temperature

    0°C to +40°C

    Relative Humidity

    15% to 95%

    Sound Output

    85dB

    Warranty

    5 Years

    Weight 0.56kg
    Product Datasheets

    Looking for more information?

    If you have any questions or would like more information about this product you can ask one of our specialists.

    Live Chat Available Now
    Direct Telephone 01507 464181

    Settings

    Colour Scheme

    Light
    Dark

    Pricing Display

    Inc VAT
    Ex VAT

    Cookies

    By continuing to browse this site you agree to the use of cookies.