The Ei3018RF is a mains powered carbon monoxide alarm with a rechargeable lithium backup in case of mains failure. Fitted with a high performance electrochemical sensor which has been individually calibrated and tested in CO gas to ensure accuracy, this alarm contains AudioLINK technology allowing you to extract real time data from the alarm, directly to your smart phone. The alarm can also be interlinked with up to 12 other alarms using a wired or wireless connection when used in conjuction with the Ei3000MRF SmartLINK module which is supplied in this bundle. The SmartLINK module will soon be capable of sending real time notifications of alarm activations via email or text.
- Product Lifespan: 10 years
- Power: 230V mains powered with battery backup
- Backup Battery: Re-chargeable lithium battery
- Warranty: 5 year warranty
- Suitable for ceiling installation
- CE and Kitemarked to BS EN 50291-1
- Supplied as an Ei3018 CO Alarm and separate Ei3000MRF SmartLINK module
- Allows for hybrid (wired or wireless) interlinking with 12 compatible devices
- technology allows for real time data extraction to a smart phone
- High performance electrochemical sensor designed to detect the prescence of CO
- Performs self-checks to ensure component functionality
- Supplied with an Easi-fit baseplate
- offers many new features
- 85dB warning alarm at 3m
- Combined test and silence button
- - allows previously activated alarms to be easily identified
- This alarm is also suitable for the updated 2022 Scottish legislation for fire alarms in homes
The table below shows all the units that can interlink with the Ei3018RF.
Smoke and Heat Alarms - Radio
Model Number
|
Type of Unit
|
Type of Interlink
|
Ei3014 / Ei3014RF |
Mains Powered Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3016 / Ei3016RF |
Mains Powered Optical Smoke Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3024 / Ei3024RF |
Mains Powered Optical & Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3028 / Ei3028RF |
Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei2110e / Ei2110eRF |
Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei161e / Ei161eRF |
Mains Powered Ionisation Smoke Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei164e / Ei164eRF |
Mains Powered Heat Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei166e / Ei166eRF |
Mains Powered Optical Smoke Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei141 / Ei168RC141RC |
Mains Powered Ionisation Alarm - 9V Alkaline |
Hardwire or Radio Interlink |
Ei144 / Ei168RC144RC |
Mains Powered Heat Alarm - 9V Alkaline |
Hardwire or Radio Interlink |
Ei146 / Ei168RC146RC |
Mains Powered Optical Smoke Alarm - 9V Alkaline |
Hardwire or Radio Interlink |
Ei3100RF |
Battery Powered Ionisation Smoke Alarm - 9V Alkaline |
Radio Interlink |
Ei3103RF |
Battery Powered Heat Alarm - 9V Alkaline |
Radio Interlink |
Ei3105RF |
Battery Powered Optical Smoke Alarm - 9V Alkaline |
Radio Interlink |
Ei603RF |
Battery Powered Heat Alarm - Sealed Lithium |
Radio Interlink |
Ei650RF |
Battery Powered Optical Smoke Alarm - Sealed Lithium |
Radio Interlink |
Carbon Monoxide Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei3018 / Ei3018RF |
Mains Powered Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei3028 / Ei3028RF |
Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei262 |
Mains Powered Carbon Monoxide Alarm - Sealed Lithium |
Hardwire or Radio Interlink |
Ei261 |
Mains Powered Carbon Monoxide Alarm - Sealed Lithium |
Hardwire Interlink |
Ei208WRF |
Battery Powered Carbon Monoxide Detector - Sealed Lithium |
Radio Iinterlink |
Ancillary Products
Model Number
|
Type of unit
|
Type of interlink
|
Ei170RF |
Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium |
Radio Interlink |
Ei407 |
Battery Powered Manual Call Point - Sealed Lithium |
Radio Interlink |
MCP401RC |
Mains Powered Manual Call Point |
Hardwire Interlink |
Ei450 |
Battery Powered Fire and CO Alarm Controller - Sealed Lithium |
Radio Interlink |
Ei411H |
Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium |
Radio Interlink |
Ei410TRF |
Battery Powered Test Remote - Sealed Lithium |
Radio Interlink (Ei3100RF Series) |
Ei1529RC |
Mains Powered Locate, Silence & Test Control Switch |
Hardwire Interlink |
Ei159 |
Mains Powered Smoke Alarm Locator Switch |
Hardware Interlink |
Ei428 |
Mains Powered 5A Relay Module |
Radio Interlink |
Ei128R |
Mains Powered 5A Relay Module |
Hardwire Interlink |
Ei128RBU |
Mains Powered 5A Relay Module with Lithium Backup Battery |
Hardwire Interlink |
Y03 |
Mains Powered Multi Frequency Sounder |
Hardwire Interlink (via relay) |
SAB300C |
Mains Powered Flashing Xenon Strobe (Clear) |
Hardwire Interlink (via relay) |
SAB300R |
Mains Powered Flashing Xenon Strobe (Red) |
Hardwire Interlink (via relay) |
Wiring Explained
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-