  • Available in Optical, Heat and Combined Optical and Heat
  • Mains powered alarms with tamper-proof lithium back-up batteries
  • Suitable for BS 5839-6: 2019 Grade D1 installations
  • Supplied with an Ei3000MRF SmartLINK Module for radio-interlinking
  • Hybrid (wired or wireless) interlinking with up to 12 compatible devices
  • Please note: alarms are sold individually
  • Also suitable for both the Welsh and Scottish 2022 legislation

£99.79 inc VAT

£83.16 ex VAT

View Product
Product Overview

Fitted with a lifetime self-charging lithium back-up battery, the Ei160eRF series of mains powered radio-interlinked alarms are ideal for use where annual battery replacement and installing interlinking cables would be unsuitable. The RadioLINK module supplied with each alarm simply plugs into the back of the unit and enables up to 12 smoke and heat alarms to wirelessly interlink within a single system. All alarms are CE marked and Kitemarked to the latest standards.

  • 230V mains powered alarms with sealed self-charging lithium battery – never needs replacing!
  • CE marked and Kitemarked to EN 14604: 2005 (smoke alarms) and BS 5446-2: 2003 (heat alarm)
  • Each alarm consists of a RadioLINK module and an Ei160e series smoke or heat alarm
  • Available in three versions:
    • Ionisation smoke alarm (Ei161eRF) for fast flaming fires - used in upstairs landings (discontinued)
    • Optical smoke alarm (Ei166eRF) for slow smouldering fires - used in bedrooms, living rooms and hallways (discontinued)
    • Heat alarm (Ei164eRF) - used in kitchens and garages (discontinued)
  • 5 year manufacturer's warranty
  • Suitable for installations complying to BS 5839-6: 2019 Grade D1
  • A maximum of 12 alarms can be interlinked within the same system
  • Wireless interlinking - requires no cables between each unit
  • Radio-frequency range: 100m in free space, up to 30m in buildings
  • Sealed back-up battery designed to last the life of the alarms (10 years)
  • Frustration-free! No more beeping during the night because the battery needs changing
  • Ideal for applications where changing batteries and interlinking cables would be inconvenient
  • RadioLINK module simply plugs into the back of the alarms
  • Features test and hush button facility
  • Memory feature – easy to identify an alarm that has previously activated
  • An interlinked system provides the earliest possible warning of fire
  • Please note: alarms are sold individually
  • This alarm is also suitable for the updated 2022 Scottish legislation for fire alarms in homes
Interlink

The table below shows all the units that can interlink with the EI160 Series.

Smoke and Heat Alarms - Radio

Model Number
Type of Unit
Type of Interlink
Ei3014 / Ei3014RF Mains Powered Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3016 / Ei3016RF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3024 / Ei3024RF Mains Powered Optical & Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei2110e / Ei2110eRF Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei161e / Ei161eRF Mains Powered Ionisation Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei164e / Ei164eRF Mains Powered Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei166e / Ei166eRF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei141 / Ei168RC141RC Mains Powered Ionisation Alarm - 9V Alkaline Hardwire or Radio Interlink
Ei144 / Ei168RC144RC Mains Powered Heat Alarm - 9V Alkaline Hardwire or Radio Interlink
Ei146 / Ei168RC146RC Mains Powered Optical Smoke Alarm - 9V Alkaline Hardwire or Radio Interlink
Ei3100RF Battery Powered Ionisation Smoke Alarm - 9V Alkaline Radio Interlink
Ei3103RF Battery Powered Heat Alarm - 9V Alkaline Radio Interlink
Ei3105RF Battery Powered Optical Smoke Alarm - 9V Alkaline Radio Interlink
Ei603RF Battery Powered Heat Alarm - Sealed Lithium Radio Interlink
Ei650RF Battery Powered Optical Smoke Alarm - Sealed Lithium Radio Interlink

Carbon Monoxide Alarms

Model Number
Type of unit
Type of interlink
Ei3018 / Ei3018RF Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei262 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei261 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink
Ei208WRF Battery Powered Carbon Monoxide Detector - Sealed Lithium Radio Iinterlink

Ancillary Products

Model Number
Type of unit
Type of interlink
Ei170RF Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium Radio Interlink
Ei407 Battery Powered Manual Call Point - Sealed Lithium Radio Interlink
MCP401RC Mains Powered Manual Call Point Hardwire Interlink
Ei450 Battery Powered Fire and CO Alarm Controller - Sealed Lithium Radio Interlink
Ei411H Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium Radio Interlink
Ei410TRF Battery Powered Test Remote - Sealed Lithium Radio Interlink (Ei3100RF Series)
Ei1529RC Mains Powered Locate, Silence & Test Control Switch Hardwire Interlink
Ei159 Mains Powered Smoke Alarm Locator Switch Hardware Interlink
Ei428 Mains Powered 5A Relay Module Radio Interlink
Ei128R Mains Powered 5A Relay Module Hardwire Interlink
Ei128RBU Mains Powered 5A Relay Module with Lithium Backup Battery Hardwire Interlink
Y03 Mains Powered Multi Frequency Sounder Hardwire Interlink (via relay)
SAB300C Mains Powered Flashing Xenon Strobe (Clear) Hardwire Interlink (via relay)
SAB300R Mains Powered Flashing Xenon Strobe (Red) Hardwire Interlink (via relay)

Wiring Explained

Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.

To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-

Wiring Mains Powered Alarms

Technical Data
Product Code

Ei164eRF Radio-Interlinked Heat Alarm:  EI164ERF

Brand EI Electronics
Back-Up Battery

Self-Charging Lifetime Lithium Battery

Dimensions

Ei161e Ionisation Alarm: (HxDia) 54x148mm

Ei166e Optical Alarm: (HxDia) 54x148mm

Ei164e Heat Alarm: (HxDia) 63x148mm

Ei100MRF RadioLINK Module: (HxW) 37x150mm

Operating Temperature

0 °C to +40 °C

Radio-Frequency Range

Free Space: Up to 100m

In Buildings: Up to 30m

Relative Humidity

15% to 95%

Sound Output

85dB

Weight

EI164ERF: 0.543kg

Product Datasheets

Customer Reviews

11 customers have given this product an overall rating of 4.7 out of 5

Reviews by real customers

All of our product reviews are written by real customers that have purchased this product from us and are published without modification.

Rating: 5 / 5 Stars

Reviewed by:

Discreet and effective!

Published on: 28th October 2017

Rating: 5 / 5 Stars

Reviewed by:

Good quality, certainly for the price.

Published on: 28th October 2017

Rating: 5 / 5 Stars

Reviewed by:

Easy Set up Exceptional company to deal with

Published on: 26th June 2017

Show More

Looking for more information?

If you have any questions or would like more information about this product you can ask one of our specialists.

Live Chat Available Now
Direct Telephone 01507 464181

Settings

Colour Scheme

Light
Dark

Pricing Display

Inc VAT
Ex VAT

Cookies

By continuing to browse this site you agree to the use of cookies.