Product Overview

Fitted with a sealed re-chargeable lithium back-up battery, the Ei160eRF series of mains powered radio-interlinked alarms are ideal for use where annual battery replacement and installing interconnecting cables would be unsuitable. The RadioLINK module supplied with each alarm simply plugs into the back of the unit and enables up to 12 smoke and heat alarms to wirelessly interlink within a single system. All alarms are CE marked and Kitemarked to the latest standards.

  • 230V mains powered alarms with re-chargeable lithium back-up battery
  • CE marked and Kitemarked to EN 14604: 2005 (smoke alarms), BS 5446-2: 2003 (heat alarm)
  • Each alarm consists of a RadioLINK module and an Ei160e series smoke or heat alarm
  • Available in three versions:
    • Ionisation smoke alarm (Ei161eRF) for fast flaming fires - used in upstairs landings
    • Optical smoke alarm (Ei166eRF) for slow smouldering fires - used in bedrooms, living rooms and hallways
    • Heat alarm (Ei164eRF) - used in kitchens and garages
  • 5 year manufacturers warranty
  • Suitable for installations complying to BS 5839-6: 2013 Grade D, E and F
  • A maximum of 12 alarms can be interlinked within the same system
  • Wireless interconnection - rerquires no cables between each unit
  • Radio-frequency range: 100m in free space, up to 30m in buildings
  • Sealed back-up battery designed to last the life of the alarms (10 years)
  • Ideal for applications where changing batteries and interconnecting cables would be inconvenient
  • RadioLINK module simply plugs into the back of the alarms
  • Features test and hush button facility
  • Memory feature - easy to identify an alarm that has previously activated
  • An interlinked system provides the earliest possible warning of fire
  • Alarms sold separately
Interconnection

The table below shows all the units that can interconnect with the EI160eRF series.

Alarms from the Same Series
Model Number
Type of unit
Type of interconnection
Ei161eRF Ionisation Smoke Alarm Radio-interlinked using the Ei100MRF module
Ei164eRF Heat Alarm Radio-interlinked using the Ei100MRF module
Ei166eRF Optical Smoke Alarm Radio-interlinked using the Ei100MRF module
Compatible Alarms
Model Number
Type of unit
Type of interconnection
Ei605TYCRF Optical Alarm Radio-interlinked
EI603TYCRF Heat Alarm Radio-interlinked
Ei168RC/Ei2110 Multi Sensor Smoke & Heat Alarm Radio-interlinked using the Ei168RC base
Carbon Monoxide Alarms
Model Number
Type of unit
Type of interconnection
Ei208WRF Battery powered CO detector Radio-interlinked
Ei262 Mains powered CO detector Radio-interlinked
Ancillary Products
Model Number
Type of unit
Type of interconnection
Ei407 Wireless Manual Call Point Radio-interlinked
Ei411H Wireless Locate, Hush and Remote Test Switch Radio-interlinked
Ei412 Wireless Fire and CO Alarm Control Switch Radio-interlinked
Ei450 Wireless Fire and CO Alarm Controller Radio-interlinked

Wiring Explained

The radio interlinked Ei160eRF series of alarms require a 230V AC mains power supply to each unit. Up to 12 alarms can be wirelessly interconnected by radio signal.

To obtain a mains feed, each alarm can be connected to its nearest lighting circuit using 2 core and earth cable. Please note that the separate lighting circuits must have a permanent live supply to all alarms. Radio frequency signals are then used for the wireless interconnection. Please see the diagram below:-


radio-interconnection-wiring
Technical Data

This is the technical data for the Aico Mains Powered Radio-Interlinked Smoke Alarms with Lithium Back-up Battery Ei160eRF Series.

Back-Up Battery Re-chargeable Lithium Battery
Sound Output 85dB at 3m
Operating Temperature 0 °C to +40 °C
Relative Humidity 15% to 95%
Radio-Frequency Range Free Space: Up to 100m
In Buildings: Up to 30m
Dimensions Ei161e Ionisation Alarm: (HxDia) 54x148mm
Ei166e Optical Alarm: (HxDia) 54x148mm
Ei164e Heat Alarm: (HxDia) 63x148mm
Ei100MRF RadioLINK Module: (HxW) 37x150mm

Technical Data Sheets

The following technical data sheets are available for this product:

Pricing & Availability

Model Stock Levels Price Weight
Ei161eRF - Radio-Interlinked Ionisation Smoke Alarm
Product Code: EI161ERF
Lead Time: 2–3 days

£68.39 ex VAT

£82.07 inc VAT

0.56kg
Ei166eRF - Radio-Interlinked Optical Smoke Alarm
Product Code: EI166ERF
Lead Time: 2–3 days

£76.89 ex VAT

£92.27 inc VAT

0.571kg
Ei164eRF - Radio-Interlinked Heat Alarm
Product Code: EI164ERF
Lead Time: 2–3 days

£81.19 ex VAT

£97.43 inc VAT

0.543kg

Customer Reviews

1 customers have rated this product and it has an overall rating of 5 out of 5

All our reviews are written by real customers that have purchased this product from us and are publsihed without modification.

5 / 5 Stars

Reviewed by: CR

Easy to fit, slightly tricky to set up, but works well.

Published on: 28th October 2016

Delivery Options

The following delivery options are available on this product.

Economy Delivery

Delivered in 4-6 working days by Royal Mail from £3.90 ex VAT - More info

Express Delivery

Delivered in 2-3 days by our specialist courier from £6.50 ex VAT - More info

Looking for more information?

If you have any questions or would like more information about this product you can ask one of our specialists.

Live Support Not Available
Direct Telephone 01507 464181
Direct Email Email Now
Tel: 0800 612 6537
Email: support@safelincs.co.uk