The table below shows all the units that can interlink with the EI262.
Model Number
|
Type of unit
|
Type of interlink
|
Ei450 |
Wireless Fire and CO Alarm Controller |
Radio-interlinked |
Q. Are there any restrictions to the distance a radio-interlinked smoke alarm will work?
A. Most radio-interlinked alarms have a range of 150 meters in an open space and up to 30 meters in buildings. The thickness of the walls and partitions will affect the travel distance of the signal.
Q. Where more than one radio-interlinked battery operated smoke alarm is installed, if the battery in one alarm failed would the other alarms be affected?
A. If one alarm was to malfunction the other units would not be affected, if it was due to alarm failure. If the fault was with the radio-interlinking signal, then all alarms that are in the chain after the faulty alarm would be affected and they would not go off.
Q. Is there a carbon monoxide alarm for the hearing impaired?
A. Yes, we supply a strobe and vibration pad for the deaf and hard of hearing, Ei170RF, which can be linked to a mains powered carbon monoxide alarm, Ei262.
Q. Can the Ei160 RF series be connected to a CO detector?
A. Yes, you can use either the battery powered Ei208WRF CO detector or the mains powered Ei262 CO detector. We also recommend that you fit a Ei412 locator switch to allow you to find out if an alarm was caused by CO gas or a fire!
Q. Please could you explain how the repeater function works on the Aico/Ei radio interlinked detectors.
A. Hello. The radioLINK repeater function allows the smoke alarm to "repeat" the radio frequency signal around obstructions. This stops the signal from becoming blocked and ensures that all interlinked alarms can be reached. This repeater function is built-in to the the Ei168RC radioLINK base (with Ei140, Ei160 or Ei2110 alarm), the Ei600 series of radio interlinked battery powered smoke and heat alarms as well as the Ei262 and Ei208WRF carbon monoxide alarms as standard. When house coded, the system works itself out which alarms are to act as repeaters - it's not something you set up yourself.
Q. Question regarding the Ei262 CO alarm and the Ei161 and Ei164 smoke and heat alarms - do I need to have a base unit for each of these items to allow them to radio interlink together?
A. The Ei161 smoke alarm and the Ei164 heat alarm each require a radio interlink base for the interconnection to be achieved. The radio-interlink based is called the Ei168RC. In terms of the Ei262 CO alarm, this does not need a separate base plate. This is because the radio-interconnection is built into the alarm.