This alarm is the radio-interlinked version of the Ei2110e, a multi-sensor fire alarm that contains two separate sensing elements – optical and heat. As the unit monitors two different by-products of fires (smoke and temperature), its response to all types of fire is vastly improved over traditional single sensor alarms and reduces the number of false alarms in the premises.
Please Note: These units use the radio-interlink frequency 868.499MHz. This bandwidth is restricted for safety products, therefore the chances of interference should be limited.
The table below shows all the units that can interlink with the Ei2110eRF.
Compatible Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei650RF | Battery powered optical alarm | Radio-interlinked |
EI603RF | Battery powered heat alarm | Radio-interlinked |
Ei161eRF | Mains powered ionisation alarm | Radio-interlinked using the Ei100MRF Module |
EI164eRF | Mains powered heat alarm | Radio-interlinked using the Ei100MRF Module |
Ei166eRF | Mains powered optical alarm | Radio-interlinked using the Ei100MRF Module |
Model Number
|
Type of unit
|
Type of interlink
|
Ei208WRF | Battery powered CO detector | Radio-interlinked |
Ei262 | Mains powered CO detector | Radio-interlinked |
Model Number
|
Type of unit
|
Type of interlink
|
Ei407 | Wireless Manual Call Point | Radio-interlinked |
Ei411H | Wireless Locate, Hush and Remote test switch | Radio-interlinked |
Ei450 | Wireless Fire and CO Alarm Controller | Radio-interlinked |
The radio interlinked Ei2110 multi-sensor alarm requires a 230V AC mains power supply to each unit. Up to 12 Ei2110 and Ei160 series of alarms can be wirelessly interlinked by radio signal.
To obtain a mains feed, each alarm can be connected to its nearest lighting circuit using 2 core and earth cable. Please note that the separate lighting circuits must have a permanent live supply to all alarms. Radio frequency signals are then used for the wireless interlink. Please see the diagram below:-
This is the technical data for the Mains Powered Radio-Interlinked Combined Optical Smoke and Heat Alarm with Lithium Back-up Battery - Ei2110eRF.
Product Code | EI2110ERF |
---|---|
Alternative Product Codes | Ei2110, Ei2110e, Ei2110eRF |
Weight | 0.32kg |
Back-Up Battery | Rechargeable Lithium |
Sound Output | 85dB (minimum) at 3m |
Temperature Range | 0°C to 40°C |
Humidity Range | 15% to 95% Relative Humidity |
Dimensions (HxDia) | 152x50mm |
The following datasheets are available for this product.
Q. For mains powered Aico smoke and heat alarms, when the electricity supply fails and the back up battery takes over, please can you tell me how long the battery will last in this situation?
A. For mains powered Aico alarms with a new, fully charged lithium back up battery, the battery would last approx. 3-6 months without a mains supply. For mains powered Aico alarms with a standard alkaline back up battery, the battery would last up to a year without mains supply. If the alarm has been installed with an Ei168RC radio frequency base, please note that the Ei168RC back up battery would last approx 2 months if the power fails.
Q. Does this alarm conform to BS 5446 part 1 as recommended by the Fire Service?
A. BS 5446-1:2000 was withdrawn in 2008 and replaced by BS EN 14604:2005 to conform with European standards. These alarms are fully compliant with BS EN 14604:2005.
Q. Can the mains powered smoke alarm range be connected to mains power via the lighting circuit?
A. Yes, hard-wired mains powered alarms can be wired to the unswitched live feed of the nearest frequently used lighting circuit.
Q. Does the Ei2110 multi sensor model need to be fitted by a qualified electrician?
A. We would always recommend a qualified electrician to fit these mains powered smoke alarms for you .
Q. What sort of smoke alarm system would I need to install for a HMO?
A. BS 5839-6 recommends that one or two storey HMOs with an individual floor area of no more than 200sqm (not the total of both floors) should have a Grade D smoke alarm system installed. Grade D refers to mains powered smoke alarms with a back up battery power supply. The alarms can be interlinked either by wire or by radio signal and the system does not require a separate fire alarm panel. For HMOs of 3 storey or higher, a Grade A panel system would need to be installed. This can cover the whole of the building, or can be used just for the communal areas with a separate Grade D system installed for the individual dwellings. For both applications, the level of cover should be a minimum of LD3 (in all escape routes) but this may change according to the fire risk assessment.
Show all FAQsModel | Stock | Price | Weight |
---|---|---|---|
Product Code: EI2110ERF |
Stock Level:
3 in stock Expected dispatch: 23rd Apr
|
Price:
£122.03 inc VAT £101.69 ex VAT |
Weight:
0.32kg
|
The following delivery options are available on this product.
If you have any questions or would like more information about this product you can ask one of our specialists.