Fitted with heat and carbon monoxide sensors, the Ei3028 is a mains powered combined alarm that can be hardwired with up to 12 other compatible alarms. Fitted with a central test and silence button and tamper-proof, rechargeable lithium back-up battery, this alarm features AudioLINK technology allowing you to extract real time data from the alarm directly to your smart phone. The Ei3028 performs its own self tests every 48 seconds and is compatible with the Ei3000MRF SmartLINK module which allows for radio-interlinking between alarms.
The tables below show all the products that can interlink with the Ei3028.
More products may be compatible when installed in conjunction with the Ei3000MRF SmartLINK module. Please see the Ei3028RF bundle for further information.
Smoke and Heat Alarms
Model Number
|
Type of Unit
|
Type of Interlink
|
Ei3014 / Ei3014RF | Mains Powered Heat Alarm - Sealed Lithium | Hardwire Interlink |
Ei3016 / Ei3016RF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Hardwire Interlink |
Ei3024 / Ei3024RF | Mains Powered Optical & Heat Alarm - Sealed Lithium | Hardwire Interlink |
Ei3028 / Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Hardwire Interlink |
Ei2110e / Ei2110eRF | Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium | Hardwire Interlink |
Ei161e / Ei161eRF | Mains Powered Ionisation Smoke Alarm - Sealed Lithium | Hardwire Interlink |
Ei164e / Ei164eRF | Mains Powered Heat Alarm - Sealed Lithium | Hardwire Interlink |
Ei166e / Ei166eRF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Hardwire Interlink |
Ei141 / Ei168RC141RC | Mains Powered Ionisation Alarm - 9V Alkaline | Hardwire Interlink |
Ei144 / Ei168RC144RC | Mains Powered Heat Alarm - 9V Alkaline | Hardwire Interlink |
Ei146 / Ei168RC146RC | Mains Powered Optical Smoke Alarm - 9V Alkaline | Hardwire Interlink |
Carbon Monoxide Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei3018 / Ei3018RF | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire Interlink |
Ei3028 / Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Hardwire Interlink |
Ei261 | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire Interlink |
Ancillary Products
Model Number
|
Type of unit
|
Type of interlink
|
MCP401RC | Mains Powered Manual Call Point | Hardwire Interlink |
Ei1529RC | Mains Powered Locate, Silence & Test Control Switch | Hardwire Interlink |
Ei159 | Mains Powered Smoke Alarm Locator Switch | Hardware Interlink |
Ei128R | Mains Powered 5A Relay Module | Hardwire Interlink |
Ei128RBU | Mains Powered 5A Relay Module with Lithium Backup Battery | Hardwire Interlink |
Y03 | Mains Powered Multi Frequency Sounder | Hardwire Interlink (via relay) |
SAB300C | Mains Powered Flashing Xenon Strobe (Clear) | Hardwire Interlink (via relay) |
SAB300R | Mains Powered Flashing Xenon Strobe (Red) | Hardwire Interlink (via relay) |
Wiring Explained
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting all alarms. However, if possible it is recommended that the alarms are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-
Product Code | EI3028 |
---|---|
Brand | EI Electronics |
Back-Up Battery | 10 year sealed lithium |
Dimensions (HxDia) | 66x150mm |
Operating Temperature | 0°C to 35°C |
Relative Humidity | 15% to 95% Relative Humidity |
Sound Output | 85dB |
Weight | 0.38kg |
Product Datasheets |
CO detectors should be installed near boilers and other potential sources of carbon monoxide. Keep a 1 to 3 meter distance to the boiler etc to avoid small start-up CO discharges to cause false alarms.
As you are likely to be most affected by CO in areas of your home that you spend the most time in it is advisable to install detectors in those areas as well, such as the living room and bedrooms.
It is also worth noting that while one detector is better than no detectors at all, larger homes may require several detectors to cover the property fully.
Which areas to avoid?
Do not install CO alarms above or below windows.
Although most kitchens contain fuel burning appliances it is not recommended to install your detector there. Kitchens can be quite steamy while you are cooking and this may affect the sensor in the CO detector. Similarly it is not recommended to install detectors in dusty areas such as workshops or garages.
For more information please watch our video guide
Safelincs is signed up to Valpak's WEEE (Waste Electrical and Electronic Equipment) Distributor Take-Back Scheme (Registration ID: 7370). Private households can therefore drop off their electronic and electrical fire safety waste at their municipal recycling centre when they are purchasing new products from us. To find your nearest recycling centre, please visit www.recycle-more.co.uk.
Yes, hard-wired mains powered alarms can be wired to the unswitched live feed of the nearest frequently used lighting circuit.
The 9V alkaline batteries last 12-18 months. Lithium batteries will usually last 5x longer than their alkaline counterparts, achieving around 5 years lifetime. Some lithium cells are also rechargeable, and when used in a mains-powered alarm may last for the entire functional lifespan of the alarm. Newer alarm models may also feature a "sealed" lithium battery. These batteries are specialist components which are designed to not be removed or need replacing by the user, and have been tested by the alarm manufacturer to ensure they last for the lifetime of the alarm.
Please Note: the actual lifetime of your batteries depends on how often the alarms are tested or activated, as sounding the alarm draws more power than when the alarms are "waiting" to detect fire. You should also read your alarm's manual to make sure you only use the recommended types and brands of batteries, as failing to follow these instructions may cause the alarm to malfunction, not alerting you in the event of a fire, and might also invalidate the warranty.
Yes, by pressing the test button on one alarm all the units in that family will also be activated. To 'teach' the units which other smoke alarms belong to the same family, the smoke alarms have to be set up together during the installation. This is done by pressing a 'housecoding button' or similar process.
It is necessary that an electrician installs mains powered smoke alarms.
All our mains powered alarms have a battery backup. Although mains powered alarms without this option do exist (BS5839 part 6 grade E), we regard them as far too dangerous, as a lot of fires are caused by electrical faults leaving the building unprotected against fire if the smoke alarms have no backup battery. With our mains powered alarms you will always be protected.
Model | Stock | Price |
---|---|---|
Product Code: EI3028 |
Stock Level:
12 in stock Expected dispatch: 19th Jan
|
Price:
£71.99 inc VAT £59.99 ex VAT |
Approved Partner
The following delivery options are available on this product.
2 customers have given this product an overall rating of 5 out of 5
Rating: 5 / 5 Stars
Reviewed by: D G
does what it says it does
Published on: 12th January 2021
Rating: 5 / 5 Stars
Reviewed by: D C
Easy to fit, located onto base well, Audio Link excellent
Published on: 22nd December 2020
If you have any questions or would like more information about/ this product you can ask one of our specialists.