9V Battery Powered Radio-Interlinked Optical Alarm - Ei605CRF

Discontinued Product

This product has been discontinued.

alternative product

Ei650RF 10 Year Wireless Optical Alarm

  • Battery: Built-in, lasts the lifetime of your alarm
  • Warranty: 5 year warranty
  • Wirelessly interlinks via radio frequency with up to 12 alarms
  • Twist-on base, simple to install
  • LED function indicators
  • Suitable for BS 5839-6: 2019 Grade F1 installations
  • Certified to BS EN 14604: 2005
  • Also suitable for the 2022 Scottish legislation

£130.39 inc VAT

£108.66 ex VAT

View Product
Product Overview

The Ei605CRF is a 9V alkaline battery powered radio-interlinked optical smoke alarm. Using the built-in RadioLINK module the Ei605CRF can be wirelessly interlinked with up to 11 other Aico and Ei Electronics products, while the stylish design ensures that these detectors never look out of place and are suitable for modern installations.

  • Battery powered smoke alarm – 9V alkaline battery included
  • 5 year manufacturer's warranty
  • Up to of 12 RadioLINK smoke alarms or heat alarms can be installed
  • RF range 100 metres (minimum) in free space and up to 30 metres in buildings
  • Built-in radioLINK repeater function ensure maximum protection
  • Suitable for installations complying to BS 5839-6: 2013 Grade F
  • Red LED alarm status indicator and blue LED RadioLINK status indicator
  • CE Marked and VdS approved to BS EN 14604:2005
  • Low battery warning
  • With test and hush button
  • Requires no cables between units and no power supply
  • Digitally coded to avoid interference with neighbouring systems
  • Supplied with fixings; 2 x screws and 2 x rawl plugs
Technical Data
Product Code EI605CRF
Alternative Product Codes EI605CRF, EI605, EI605RF, EI605TYC, EI605TYCRF, EI605C
Brand EI Electronics
Battery Life

Approximately 12 months

Battery Type

9V PP3 Alkaline

Dimensions (HxDia)

55x115mm

Operating Temperature

Operating: 0°C to +40°C

Storage: 0°C to +35°C

Radio Linking Frequency

868.499MHz

Radio-Frequency Range

Clear Line of Sight: 100m

Typical Property: 30m

Relative Humidity

15% to 95% Relative Humidity

Sensor Type

Optical Smoke Sensor

Sound Output

85dB

Weight 0.20kg
Product Datasheets
FAQs (9)
Q. How can we test the alarm to make sure it is working?
A.

The manufacturer's recommendation is to test the alarm by pressing the test button. This will simulate a heat input at the heat sensor. You can also test it with a hair dryer but make sure that the hairdryer is kept away at a suitable distance from the alarm. Do not attempt to test the alarm by using open fire or excessive heat as this may damage the unit.

Q. Is it possible to have a heat alarm mains powered radio interlinking alarm interconnect with battery powered radio-interlinked alarms?
A.

Yes this entirely possible. The Ei140 series with RF base is mains powered and these are compatible to interlink with the battery operated Ei3100 series. Please view the interconnection overview on either of these alarms for further details.

Q. Do the Ei600 series alarms need 230v or do they just use battery?
A.

The Ei600 series of radio-interlinked alarms are completely battery operated. This means that they do not need to be wired up to the mains circuit. On the website, we offer the Ei600 series with a standard 9v battery or with a 10 year lithium longlife battery. The standard 9V batteries last approximately 12-18 months depending on how often the detectors are tested. The lithium battery units are sealed and last 10 years i.e. the full lifespan of the detector.

Q. Where more than one radio-interlinked battery operated smoke alarm is installed, if the battery in one alarm failed would the other alarms be affected?
A.

If one alarm was to malfunction the other units would not be affected, if it was due to alarm failure. If the fault was with the radio-interlinking signal, then all alarms that are in the chain after the faulty alarm would be affected and they would not go off.

Q. What is the difference between Ei605TYCRF and Ei605CRF smoke alarms, can both be used with the EI412 remote control panel?
A.

The Ei605TYCRF comes with a ten year lithium battery, this should last for the life span of the alarm. The Ei605CRF comes with an alkaline battery that will need to be changed every 12 months. As these alarms are part of the Ei600 series they are both compatible with the Ei412.

Q. Do the radio interlinked units give out a constant signal all the time and does this decrease the battery life more than a non-interlinked alarm?
A.

Yes, radio interlinked alarms are periodically sending and receiving signals from other units in the network and therefore the life of the battery is reduced. Units with alkaline batteries should have the batteries are changed annually [unless they are fitted with a sealed 10 year battery as eg in the Ei600RF series].

Q. If the radio interlinking signal on one unit fails will the units still work as stand alone units.
A.

Yes, should the radio interlinking signal fail the units will continue to sound independently should they detect a fire.

Q. What is the difference between Ei3100RF radio-interlinked smoke alarm series and the Ei600 series of radio-interlinked smoke alarms? Why does one cost much more than the other?
A.

The EI600RF series are a later model and on top of all the features that the Ei3100RF offers, the series has the possibility to use the locate feature in the control switch, making the product more similar to a BS5839 part 6 Grade A alarm system. Additionally, the Ei600 series smoke alarms are offered with a true ten year life sealed lithium battery which makes the alarms acceptable in most circumstances as a BS5839 part 6 Grade D fire alarm system. This offers a substantial saving to customers, as it replaces the need for an electrician installing mains powered alarms.

Q. Please could you explain how the repeater function works on the Aico/Ei radio interlinked detectors.
A.

Hello. The radioLINK repeater function allows the smoke alarm to "repeat" the radio frequency signal around obstructions. This stops the signal from becoming blocked and ensures that all interlinked alarms can be reached. This repeater function is built-in to the the Ei168RC radioLINK base (with Ei140, Ei160 or Ei2110 alarm), the Ei600 series of radio interlinked battery powered smoke and heat alarms as well as the Ei262 and Ei208WRF carbon monoxide alarms as standard. When house coded, the system works itself out which alarms are to act as repeaters - it's not something you set up yourself.

Looking for more information?

If you have any questions or would like more information about this product you can ask one of our specialists.

Live Chat Available Now
Direct Telephone 01507 464181

Settings

Colour Scheme

Light
Dark

Pricing Display

Inc VAT
Ex VAT