Ideal for home and travel use, the FireAngel CO-9B carbon monoxide alarm is suitable for wall mounting or free standing as a portable device. The FireAngel CO-9B has a 7 year lifespan and manufacturer's warranty period, and is supplied as standard with 2 x AA alkaline batteries to power the alarm. Its LED status indicators show when the alarm is correctly powered as well as when it has entered alarm mode.
- Product Life: 7 years
- Battery: AA alkaline batteries included
- Warranty: 7 year warranty
- Designed for wall mounting with simple installation
- CE marked and Kitemarked to BS EN 50291-1 (domestic use) & BS EN 50291-2:2010 (camping/caravans/boats)
- Test/reset button feature
- Activates when CO level reaches 50ppm
- Enables users to carry out a practical sensor test
- 85dB audible alarm as well as LED status indicator
- 7 year lifespan and manufacturer's warranty
- Automatic self diagnostic function - checks its own sensor and battery
- Can be wall mounted or left free standing
- Certified for home, camping, caravan, motor home and boat use
- Supplied with fixings; 2 x screws and 2 x rawl plugs
Q. What are the regulations to testing CO detectors? Do I need to use test gas?
A. There is no legal or BSI requirement to test the CO detectors with a test gas. A weekly check with the test button is fully sufficient if you choose a quality CO detector. The test gas is offered as a 'belts and braces' option.
Q. What is the best way to test my alarm?
A. We recommend testing alarms by pressing the test button built-in to the unit, as this is designed to simulate the detection of the target stimuli (usually smoke, heat, or CO) at the alarm sensor. You should test your alarms regularly to ensure they are protecting building occupants, preferably every week. For more detailed guidance, check the manual included with your alarm.
Q. How long do the batteries last in smoke alarms?
A. The 9V alkaline batteries last 12-18 months. Lithium batteries will usually last 5x longer than their alkaline counterparts, achieving around 5 years lifetime. Some lithium cells are also rechargeable, and when used in a mains-powered alarm may last for the entire functional lifespan of the alarm. Newer alarm models may also feature a "sealed" lithium battery. These batteries are specialist components which are designed to not be removed or need replacing by the user, and have been tested by the alarm manufacturer to ensure they last for the lifetime of the alarm.
Please Note: the actual lifetime of your batteries depends on how often the alarms are tested or activated, as sounding the alarm draws more power than when the alarms are "waiting" to detect fire. You should also read your alarm's manual to make sure you only use the recommended types and brands of batteries, as failing to follow these instructions may cause the alarm to malfunction, not alerting you in the event of a fire, and might also invalidate the warranty.
Q. Is this CO Detector compliant with all relevant standards to allow me to place it in a tenanted property as I am a landlord?
A. Yes, this CO alarm has been Kitemarked to EN 50291-1: 2010 and has been awarded a CE mark. It should be installed in line with the manufacturers guidance.
Q. Where should I install carbon monoxide detectors?
A. CO detectors should be installed near boilers and other potential sources of carbon monoxide. Keep a 1 to 3 meter distance to the boiler etc to avoid small start-up CO discharges to cause false alarms.
As you are likely to be most affected by CO in areas of your home that you spend the most time in it is advisable to install detectors in those areas as well, such as the living room and bedrooms.
It is also worth noting that while one detector is better than no detectors at all, larger homes may require several detectors to cover the property fully.
Which areas to avoid?
Do not install CO alarms above or below windows.
Although most kitchens contain fuel burning appliances it is not recommended to install your detector there. Kitchens can be quite steamy while you are cooking and this may affect the sensor in the CO detector. Similarly it is not recommended to install detectors in dusty areas such as workshops or garages.
For more information please watch our
Key Product Features
Large, easy-press test and hush button
Supplied complete with 2 x replaceable AA batteries
Clear, bright power and alarm LED indicators
Includes the fixings needed for installation on walls
What's Included?
Every FireAngel FACO9B is supplied with the following components.
- 1 x FireAngel CO-9B carbon monoxide alarm
- 2 x AA alkaline batteries
- 1 x Screw fixing set (screws & rawl plugs)
- 1 x Instruction manual