{"id":3190,"date":"2024-06-07T09:39:17","date_gmt":"2024-06-07T09:39:17","guid":{"rendered":"https:\/\/www.safelincs.co.uk\/blog\/?p=3190"},"modified":"2025-08-27T09:20:24","modified_gmt":"2025-08-27T09:20:24","slug":"which-emergency-light-maintained-or-non-maintained","status":"publish","type":"post","link":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/","title":{"rendered":"Maintained or Non-Maintained Emergency Lighting?"},"content":{"rendered":"\n<p id=\"block-12c8dd43-2c83-4cac-a87f-5fa63feb853c\">The installation of <a href=\"https:\/\/www.safelincs.co.uk\/emergency-lighting\/\">maintained or non-maintained<\/a> emergency lighting <strong>should be decided based upon building type, its occupants and i<\/strong>ts<strong> usage<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between maintained and non-maintained emergency lights?<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"block-34cd53c4-8a9a-4db1-ae4e-98c74c5df752\"><strong>Maintained<\/strong> Lights<\/h4>\n\n\n\n<p id=\"block-009b38db-6c01-442d-92e8-7532f2422027\"><a href=\"https:\/\/www.safelincs.co.uk\/all-emergency-lighting\/?c274=2194\">Maintained emergency lighting<\/a> is <strong>on at all times<\/strong>. These lights are <strong>mains powered<\/strong> and used as part of the normal room lighting system. However, should the mains power fail, it will stay lit for a specific duration <strong>powered by a back-up battery<\/strong>.<\/p>\n\n\n\n<p id=\"block-7fb144aa-31a4-4af9-862a-14912aac4590\">Maintained lighting could include lit fire exit signs, bulkhead lighting or recessed downlights. <\/p>\n\n\n\n<p id=\"block-009b38db-6c01-442d-92e8-7532f2422027\">This type of emergency lighting is generally used in non-residential places of public assembly such as leisure centres, cinemas, shopping centres etc. In public venues where the normal lighting is often dimmed e.g. cinemas, theatres or bars, maintained luminaries are <em>always<\/em> required.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"block-3eef263a-5087-488d-a5fa-76e11520f826\"><strong>Non-maintained<\/strong> Lights<\/h4>\n\n\n\n<p id=\"block-ecdd90a0-c043-4460-b1f7-713fb1205a35\"><a href=\"https:\/\/www.safelincs.co.uk\/all-emergency-lighting\/?c274=2193\">Non-maintained lighting<\/a> <strong>only comes on for a specific duration<\/strong> when the power supply to normal artificial lighting fails. These light fittings are <strong>powered by a battery<\/strong> that is charged from a constant trickle of mains power. This battery should have enough charge to remain lit for a duration of 3 hours if the mains power fails. Regular testing of emergency lighting is required to ensure that it is working and will be effective in an emergency. Read more about <a href=\"https:\/\/www.safelincs.co.uk\/safelincs-combined-servicing-package\/\" target=\"_blank\" rel=\"noreferrer noopener\">testing and maintenance.<\/a><\/p>\n\n\n\n<p>Non-maintained emergency lights are normally suitable for buildings which are usually lit when occupied, for example, workplaces, offices, and schools.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.safelincs.co.uk\/illuminated-fire-exit-signage\/\" title=\"Buy illuminated fire exit signs\"><img loading=\"lazy\" decoding=\"async\" width=\"810\" height=\"270\" src=\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/04\/emergency-exit-sign-light.jpg\" alt=\"Illuminated fire exit sign next to a door\" class=\"wp-image-9205\" srcset=\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/04\/emergency-exit-sign-light.jpg 810w, https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/04\/emergency-exit-sign-light-300x100.jpg 300w, https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/04\/emergency-exit-sign-light-768x256.jpg 768w\" sizes=\"auto, (max-width: 810px) 100vw, 810px\" \/><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"block-e68730ac-ccf7-4440-8e8f-ab93e62a3a6f\">Can an emergency light fitting be both maintained AND non-maintained?<\/h3>\n\n\n\n<p id=\"block-631994a8-1dd6-4f6a-9444-ec2f4d67b943\">Yes. Maintained emergency light fittings or signs used as part of a normal room lighting system can also be wired to perform as a non-maintained fitting if required. This especially useful if your property has multiple uses, where you have a mix of maintained and non-maintained lighting requirements, only one type of light needs to be purchased. Many maintained fittings are available as switchable units, meaning they can be switched between maintained and non-maintained modes using an ordinary light switch. However, non-maintained light fittings cannot be wired for use in maintained operation.<\/p>\n\n\n\n<p id=\"block-bebd2ea4-71f0-45e1-9b56-203da0adc2c5\">If you are unsure which emergency lighting is best for your environment, it is best practice to conduct a <a href=\"https:\/\/www.safelincs.co.uk\/on-site-fire-risk-assesment\/\">fire risk assessment<\/a>. This must be conducted by a \u2018<a href=\"https:\/\/www.effective-hrm.co.uk\/news\/what-is-competence-and-who-is-your-competent-person\/\" target=\"_blank\" rel=\"noreferrer noopener\">competent person<\/a>\u2019. A specialist <a href=\"https:\/\/www.safelincs.co.uk\/on-site-fire-risk-assessment\/\" target=\"_blank\" rel=\"noreferrer noopener\">risk assessor<\/a> will advise the most suitable option in line with the current regulations if your organisation cannot complete this in house.<\/p>\n\n\n\n<p id=\"block-780f9541-30c4-4687-9c89-4409b3a803a4\"><div class=\"product-box\">\r\n\t<img decoding=\"async\" src=\"https:\/\/www.safelincs.co.uk\/shopimages\/products\/high\/safelincs-fire-risk-assessment-warehouse-ben-and-matt_thumb_210.jpg\" alt=\"Fire Risk Assessments\">\r\n\t<div class=\"pb-left\">\r\n\t\t<a href=\"https:\/\/www.safelincs.co.uk\/onsite-fire-risk-assessment\/\" class=\"product-name\">Fire Risk Assessments<\/a>\r\n\t\t<ul>\r\n<li>On-site fire risk assessment (FRA)<\/li>\r\n<li>Expert advice from our qualified fire risk assessors<\/li>\r\n<li>Comprehensive report with clear indications of areas for improvement<\/li>\r\n<li>Quick and easy booking<\/li>\r\n<li>10% discount on most fire safety products<\/li>\r\n<li>FREE online fire safety management portal<\/li>\r\n<\/ul>\r\n\t<\/div>\r\n\t<div class=\"pb-right\">\r\n        <div class=\"price\">\r\n            <div class=\"price-inc\">\r\n                \u00a3315.00 ex VAT\r\n            <\/div>\r\n            <div class=\"price-ex\">\r\n                \u00a3378.00 inc VAT\r\n            <\/div>\r\n        <\/div>\r\n\t\t<a href=\"https:\/\/www.safelincs.co.uk\/onsite-fire-risk-assessment\/\" class=\"product-button\">Buy Now<\/a>\r\n\t<\/div>\r\n<\/div>\r\n<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube aligncenter wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Maintained and Non-Maintained Emergency Lighting\" width=\"660\" height=\"371\" src=\"https:\/\/www.youtube.com\/embed\/tfj9OH9bhn0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><figcaption class=\"wp-element-caption\">Watch our video to learn the difference between maintained and non-maintained emergency lighting<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"block-5987e541-377f-4f76-887b-d21ff78ddede\"><strong>Which type of emergency lighting do I need?<\/strong><\/h3>\n\n\n\n<p id=\"block-b44b90b2-3bda-44f8-b0a1-13ed933440e9\"><a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Standard?UPI=000000000030263986\" target=\"_blank\" rel=\"noreferrer noopener\">British Standards guidelines 5266-1:2011<\/a> requires emergency lighting to be installed in all high occupancy residential, public or commercial buildings. It outlines the duties of the &#8216;<a href=\"https:\/\/www.gov.uk\/government\/publications\/people-with-duties-under-fire-safety-laws\" target=\"_blank\" rel=\"noreferrer noopener\">Responsible Person<\/a>&#8216; and focuses on emergency lighting fixtures ensuring escape routes are illuminated when the mains power fails. There are often more specific requirements given by local authorities in each area; check your local government website for more information.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p id=\"block-88fec3b7-ebee-4d45-ae76-37b60ebc7a40\">Whether maintained or non-maintained emergency lighting is needed is <strong>largely a question for <a href=\"https:\/\/www.safelincs.co.uk\/onsite-fire-risk-assessment\/\">fire risk assessors<\/a> based on each individual property<\/strong>. If non-maintained lighting is deemed sufficient, it is also worth considering the reduced environmental impact and lower energy cost of using non-maintained lighting over time.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"block-0024d22f-65ea-496e-9880-db52119105d0\">Help guides<\/h4>\n\n\n\n<p id=\"block-1366f0f7-34ab-4f40-9e6d-2bac4b98d707\">More information about all aspects of emergency lighting can be found in our <a href=\"https:\/\/www.safelincs.co.uk\/emergency-lighting-guide\/\">emergency lighting guides.<\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"block-f996d967-3ef9-4ee5-a28d-79410269f239\">British Standards<\/h4>\n\n\n\n<p id=\"block-ddc7a19b-f4b9-4824-b7f6-99d128c569f7\">There are various British Standards that set out the regulations for emergency lighting where further guidance can be sought:<\/p>\n\n\n\n<ul id=\"block-7211c96c-848f-4dcb-b4cd-fc4b3137a8c7\" class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.bafe.org.uk\/bafe-fire-safety-guidance\/emergency-lighting-system-guidance\" target=\"_blank\" rel=\"noreferrer noopener\">BS5266-1<\/a> <em>Code of practice for emergency lighting of premises<\/em> sets out general guidance on what emergency lighting should be provided in each environment<\/li>\n\n\n\n<li><a href=\"https:\/\/www.firesafe.org.uk\/emergency-lighting\/\" target=\"_blank\" rel=\"noreferrer noopener\">BS EN 50172<\/a> \/ <a href=\"https:\/\/www.hse.gov.uk\/electricity\/standards.htm\" target=\"_blank\" rel=\"noreferrer noopener\">BS 5266-8<\/a> <em>Emergency escape lighting systems <\/em>details minimum emergency lighting provision and testing for each type of environment<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The installation of maintained or non-maintained emergency lighting should be decided based upon building type, its occupants and its usage. What is the difference between maintained and non-maintained emergency lights? Maintained Lights Maintained emergency lighting is on at all times. These lights are mains powered and used as part of the normal room lighting system. &hellip; <a href=\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Maintained or Non-Maintained Emergency Lighting?<\/span><\/a><\/p>\n","protected":false},"author":21,"featured_media":8976,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2595],"tags":[204,143,2177],"class_list":["post-3190","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-help-guides","tag-business","tag-emergency-lighting","tag-help-guide"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Difference Between Maintained &amp; Non-Maintained Emergency Lights<\/title>\n<meta name=\"description\" content=\"Read our help guide to find out the difference between maintained and non-maintained emergency lighting and which lights you need.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Difference Between Maintained &amp; Non-Maintained Emergency Lights\" \/>\n<meta property=\"og:description\" content=\"Read our help guide to find out the difference between maintained and non-maintained emergency lighting and which lights you need.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\" \/>\n<meta property=\"og:site_name\" content=\"Safelincs Blog\" \/>\n<meta property=\"article:published_time\" content=\"2024-06-07T09:39:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-27T09:20:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Mel Saunders\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mel Saunders\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\"},\"author\":{\"name\":\"Mel Saunders\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/person\/7185540002144694ab5fd91fee4d9ddd\"},\"headline\":\"Maintained or Non-Maintained Emergency Lighting?\",\"datePublished\":\"2024-06-07T09:39:17+00:00\",\"dateModified\":\"2025-08-27T09:20:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\"},\"wordCount\":619,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg\",\"keywords\":[\"Business\",\"emergency lighting\",\"help guide\"],\"articleSection\":[\"Help Guides\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\",\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\",\"name\":\"Difference Between Maintained & Non-Maintained Emergency Lights\",\"isPartOf\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg\",\"datePublished\":\"2024-06-07T09:39:17+00:00\",\"dateModified\":\"2025-08-27T09:20:24+00:00\",\"description\":\"Read our help guide to find out the difference between maintained and non-maintained emergency lighting and which lights you need.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage\",\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg\",\"contentUrl\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg\",\"width\":600,\"height\":600,\"caption\":\"Eden Bulkhead Emergency Light\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.safelincs.co.uk\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Maintained or Non-Maintained Emergency Lighting?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#website\",\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/\",\"name\":\"Safelincs Blog\",\"description\":\"Fire Safety News and Updates\",\"publisher\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.safelincs.co.uk\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#organization\",\"name\":\"Safelincs\",\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/05\/safelincs-logo.jpg\",\"contentUrl\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/05\/safelincs-logo.jpg\",\"width\":378,\"height\":112,\"caption\":\"Safelincs\"},\"image\":{\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/person\/7185540002144694ab5fd91fee4d9ddd\",\"name\":\"Mel Saunders\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2020\/09\/D71_6470a-e1600178010441-150x150.jpg\",\"contentUrl\":\"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2020\/09\/D71_6470a-e1600178010441-150x150.jpg\",\"caption\":\"Mel Saunders\"},\"description\":\"With over 20 years of experience in content writing, design and marketing, Mel now heads up the Content &amp; Marketing Team at Safelincs. Having been in the fire safety industry for over 5 years, Mel has now developed a deep understanding of some of the critical issues facing the industry. Alongside her team, she aims to support the public with resources and information to help them improve fire safety at home, in the workplace or in 3rd sector organisations.\",\"sameAs\":[\"https:\/\/www.linkedin.com\/in\/melanie-saunders-40930b107\/\"],\"url\":\"https:\/\/www.safelincs.co.uk\/blog\/author\/mel\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Difference Between Maintained & Non-Maintained Emergency Lights","description":"Read our help guide to find out the difference between maintained and non-maintained emergency lighting and which lights you need.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/","og_locale":"en_GB","og_type":"article","og_title":"Difference Between Maintained & Non-Maintained Emergency Lights","og_description":"Read our help guide to find out the difference between maintained and non-maintained emergency lighting and which lights you need.","og_url":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/","og_site_name":"Safelincs Blog","article_published_time":"2024-06-07T09:39:17+00:00","article_modified_time":"2025-08-27T09:20:24+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg","type":"image\/jpeg"}],"author":"Mel Saunders","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Mel Saunders","Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#article","isPartOf":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/"},"author":{"name":"Mel Saunders","@id":"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/person\/7185540002144694ab5fd91fee4d9ddd"},"headline":"Maintained or Non-Maintained Emergency Lighting?","datePublished":"2024-06-07T09:39:17+00:00","dateModified":"2025-08-27T09:20:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/"},"wordCount":619,"commentCount":0,"publisher":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/#organization"},"image":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage"},"thumbnailUrl":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg","keywords":["Business","emergency lighting","help guide"],"articleSection":["Help Guides"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/","url":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/","name":"Difference Between Maintained & Non-Maintained Emergency Lights","isPartOf":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage"},"image":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage"},"thumbnailUrl":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg","datePublished":"2024-06-07T09:39:17+00:00","dateModified":"2025-08-27T09:20:24+00:00","description":"Read our help guide to find out the difference between maintained and non-maintained emergency lighting and which lights you need.","breadcrumb":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#primaryimage","url":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg","contentUrl":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/02\/eden-8w-bulkhead-emergency-light.jpg","width":600,"height":600,"caption":"Eden Bulkhead Emergency Light"},{"@type":"BreadcrumbList","@id":"https:\/\/www.safelincs.co.uk\/blog\/2024\/06\/07\/which-emergency-light-maintained-or-non-maintained\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.safelincs.co.uk\/blog\/"},{"@type":"ListItem","position":2,"name":"Maintained or Non-Maintained Emergency Lighting?"}]},{"@type":"WebSite","@id":"https:\/\/www.safelincs.co.uk\/blog\/#website","url":"https:\/\/www.safelincs.co.uk\/blog\/","name":"Safelincs Blog","description":"Fire Safety News and Updates","publisher":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.safelincs.co.uk\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.safelincs.co.uk\/blog\/#organization","name":"Safelincs","url":"https:\/\/www.safelincs.co.uk\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/05\/safelincs-logo.jpg","contentUrl":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2021\/05\/safelincs-logo.jpg","width":378,"height":112,"caption":"Safelincs"},"image":{"@id":"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/person\/7185540002144694ab5fd91fee4d9ddd","name":"Mel Saunders","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.safelincs.co.uk\/blog\/#\/schema\/person\/image\/","url":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2020\/09\/D71_6470a-e1600178010441-150x150.jpg","contentUrl":"https:\/\/www.safelincs.co.uk\/blog\/wp-content\/uploads\/2020\/09\/D71_6470a-e1600178010441-150x150.jpg","caption":"Mel Saunders"},"description":"With over 20 years of experience in content writing, design and marketing, Mel now heads up the Content &amp; Marketing Team at Safelincs. Having been in the fire safety industry for over 5 years, Mel has now developed a deep understanding of some of the critical issues facing the industry. Alongside her team, she aims to support the public with resources and information to help them improve fire safety at home, in the workplace or in 3rd sector organisations.","sameAs":["https:\/\/www.linkedin.com\/in\/melanie-saunders-40930b107\/"],"url":"https:\/\/www.safelincs.co.uk\/blog\/author\/mel\/"}]}},"_links":{"self":[{"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/posts\/3190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/users\/21"}],"replies":[{"embeddable":true,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/comments?post=3190"}],"version-history":[{"count":25,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/posts\/3190\/revisions"}],"predecessor-version":[{"id":11700,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/posts\/3190\/revisions\/11700"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/media\/8976"}],"wp:attachment":[{"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/media?parent=3190"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/categories?post=3190"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.safelincs.co.uk\/blog\/wp-json\/wp\/v2\/tags?post=3190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}