Rafiki Twinflex Plus 8 Zone Fire Alarm Panel

£355.99 inc VAT
£296.66 ex VAT
Low Stock
Quantity
The Twinflex plus uses a detector sounder ‘logical link’ feature. This is the first time that this feature has been made available on a conventional system and is beneficial where two stage alarms are required.
  • Two wire conventional fire alarm panel
  • Innovative solution to false alarms in “Housing of Multiple Occupation"
  • Only one circuit per zone to connect detectors and sounders
  • Suitable for Installations to BS5839 part 1 and part 6
  • EN54 Pt 2 & 4 compliant
  • Easy to install
  • 72 hour standby
  • Built in auxiliary sounder
  • Panel can differentiate between call points and detectors
  • Up to 32 devices per zone

This is the technical data for the Rafiki Twinflex Plus 8 Zone Fire Alarm Panel.

Product Code SU502-0008
Weight 3.2 kg
Dimensions (HxWxD) 243x310x85mm

At the planning stage of installation fire zones are designated as ‘communal’ or ‘dwelling’. Detectors in dwelling zones (e.g. apartments, hotel rooms etc.) are enabled with the ‘logical link’ feature by way of a dip switch in the detector.

Communal Zone

Communal area, e.g. hall/stairway; kitchen; lounge

When a detector is activated on this type of zone, the control panel enters the fire state as normal and the alarms are activated immediately in all zones throughout the installation.

Single Dwelling per Zone (Zonal confirmation alarm)

eg flats with more than one room

When a detector alarm is activated on this type of zone, all sounders on the zone are activated and then the control panel carries out the configured number of confirmation checks. If the detector alarm is confirmed, the control panel enters the fire state and the alarms are activated throughout the installation; if the detector alarm is rejected, the sounders on the zone are
silenced, and the detector in alarm is reset.

Multiple Dwellings per Zone (Local confirmation alarm)

Dwellings requiring a single detector/sounder, e.g. hostel; hall of residence; hotel rooms; bedsits.

When a detector alarm is detected on this type of zone, the integral sounder in the detector that generated the alarm signal is activated and then the control panel carries out the configured number of confirmation checks. If the detector alarm is confirmed, the control panel enters the fire state and the alarms are activated throughout the installation; if the detector alarm is rejected, the sounder is silenced, and the detector reset.

Note: Activation of any manual call point will override alarm confirmation

Checkpoint Flowchart

Low Cost Delivery

From £3.50 inc VAT

View Charges

Questions? Ask our product specialist...

If you have a technical questions or a query relating to this product why not contact our product specialist. Each of our specialists have specific training targeted towards their product area.